Pular para o conteúdo principal
GE Healthcare · CTLightSpeed26011821550368

LightSpeed RT with GRE and MDAS4 gantry

Symptom

Scanner hardware stopped scan with KV errors. Scanner hardware stopped scan with Error: 260118215 (60-0318)kV did not reach 75 percent after 20ms.

Error message

Error: 260118215 (60-0318) kV did not reach 75 percent after 20ms See Long Description for full error Sat Mar 25 15:35:28 2006 Error: 260118215 Host: orp Process: orp_subsys File: gen_exec.c Line: 2150 Sat Mar 25 15:35:27 2006 Host : Jedi Ermes # : 260118215 Exception Class : Abort Severity : Primary File : gen_exec.c Line# : 2150 Function : No System Function Reported Scan Type : Static Scan: 50368/1/3 (60-0318)kV did not reach 75 percent after 20ms. Indicates that there was no HV ON signal generated for exposure time count-up.

Applies to

Models
LightSpeed
Product
LightSpeed RT4 WB O G4 G HPT WB O M4 G HPT LightSpeed RT4 with GRE and MDAS4 or GDAS4 gantry At GE Medical Systems, we’re pioneering exciting CT technology for Radiation Therapy planning. Introducing the newest addition to our LightSpeed® series – LightSpeed RT, the first multi-slice, wide-bore CT scanner with the largest field of view in the industry. With a generous 80 cm gantry opening, the LightSpeed RT bore is 10 cm larger than conventional scanners. This provides complete flexibility for patient positioning freedom – even for the most demanding oncology needs. And the 65 cm variable field of view delivers 15 additional centimeters of visual coverage, allowing clinicians to see a patient’s entire anatomy for precise radiation therapy planning. Position and precision Thin, multi-slice imaging is the extra bonus – enabling respiratory gating, providing precise target delineation and delivering higher resolution digitally reconstructed radiographs (DRRs) than ever before. All adding up to the ability for you to deliver what really matters most – better cancer care for your patients. Plus, the LightSpeed RT scanner is available with the Exact™ couch insert, enabling you to consistently replicate patient immobilization for treatment. With LightSpeed RT, the future of your Radiation Oncology department is wide open. Links to the Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Component
D3634T (aka 2378211-2 ) Varian PERFORMIX PRO TUBE used on : HP80 AND LS RT4 See Long Description for details Part #: D3634T Part Type: GP TUBES Part Weight: 176.37 LBR Repairable: No Returnable: Yes Hazardous Material: N Description: PERFORMIX PRO (VARIAN) TUBE UNIT FRU: Yes Status: Orderable Comments: FLS 11/19/04 (Shawn Fox 212001261) PLEASE remember to complete the Tube report for the tube you are replacing and return it with old tube. The blank Tube report comes with the new tube. If you have any questions, please contact Yolanda Scheper 262-548-2864. If you do not return tube report with old tube, warranty credit can be missed or delayed for your Zone
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required

Related GE Healthcare CT issues