GE Healthcare · CTLightSpeed185122182902
LightSpeed 5.X (60kW)
Symptom
Cradle will not move in or out of the Gantry. No c-pulse is being detected from longitudal encoder Cradle will not move in or out of the Gantr . No c-pulse is being detected from longitudal encoder y
Error message
Error: 185122 24V Power Supply Out Of Tolerance Sun Sep 5 16:04:34 2004 Error: 185122 Suite: RP21 Host: ETC Process: Control File: etcPowSupTest.c 1.4 2/16/99 Method: No Method Line:117 Function: No System Function Reported Scan: 0/0/0 Type: None/Unknown Exception Level: Pri/Soft Time: 3588 Log Series: 2 HW error: 24V Power Supply Out Of Tolerance: A/D reading = 0x4 Calc Voltage = 0.03 (Volts) Tolerance = 3 (Percentage) INFO: If the supply is low the problem may be that the Xray Drive Power is OFF Error: 182902 Emergency Off button has been pressed Sun Sep 5 16:04:39 2004 Error: 182902 Suite: RP21 Host: ETC Process: Table Controls File: tc emergency.c 1.6 2/16/99 Method: No Method line: 89 Function: No System Function Reported Scan: 0/0/0 Type: None/Unknown Exception Level: Pri/Soft Time: 4016 Log Series: 22 Emergency Off button has been pressed
Applies to
- Models
- LightSpeed
- Product
- LightSpeed 5.X (60kW) LightSpeed 5.X (60kW) ~ Use with MDAS or GDAS HP_P_G4 HP_P_G8 HP_P_G16 HP_P_M16 LightSpeed 5.X 60KW G-DAS16 with GRE Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Component
- 2372371 Left Table Top Cover - used on LS 2.x - 5.x tables See LD for details 2372371 HPower Left Table Top Cover 2372371 1.000 Yes COVER TABLE TOP LEFT left...... Part #: 2372371 Part Type: GP CONSUMABLES Part Weight: 0.00 LBR Repairable: No Returnable: No Hazardous Material: N Description: COVER TABLE TOP LEFT FRU: Yes Status: Orderable Comments: FLS - TABLE COVER, TOP LEFT. ADDED PER CT PCN 220864. THIS PART REPLACES P/N 2236720 ONLY ON HPOWER SYSTEMS . KEEP USING OLD P/N FOR ALL OTHER PRODUC TS. MS20544 3/31/03. Additional Left Table Top Cover information for 1.x, 2.x, 3.x, 4.x and HiSpeed QXi Systems. Part #: 2236720 <--Use this part # for 1.x, 2.x, 3.x, 4.x and HiSpeed QXi Systems Part Type: GP CONSUMABLES Part Weight: 16.01 LBR Repairable: No Returnable: No Hazardous Material: N Description: COVER ASSEMBLY TABLE TOP - LEFT FRU: Yes Status: Orderable Comments: FLS - CAN ALSO ORDER OLD COVER 2149735-2 GPC TABLE MOVE TO CHINA 5/24/0NOW ASIA SOURCED. PER PCN 220864, THIS PART HAS BEEN REPLACED BY P/N 2372371, IN ORDER TO BE USED ON HPOWER SYSTEMS. ALSO SOURCED BY ASIA. MS205444 3/31/03. DO NOT DISCOUNT - PER SHAKUN RIGHT: 2236720-2 ONE USE LIGHTSPEED FLS - PLEASE CONVERT SPH ORDER TO OVERNIGHT SHIPMENT IF PART AVAILABLE IN MEMPHIS AND IF FEDEX SERVICE (INCLUDING 8:00 AM SERVICE) MEETS FE NEED TIME CRITERIA 2372372 Right Table Top Cover - used on LS 2.x - 5.x tables See LD for details 2372372 HPower Right Table Top Cover Part #: 2372372 Part Type: GP CONSUMABLES Part Weight: 72.75 LBR Repairable: No Returnable: No Hazardous Material: N Description: COVER TABLE TOP RIGHT FRU: Yes Status: Orderable Comments: FLS - COVER TABLE, TOP RIGHT. REPLACES P/N 2236720-2 ONLY ON HPOWER SYSTEMS, PER CT PCN 220864. MS20544 3/31/03. Addtional Right Table Top Cover Information: Part #: 2236720-2 <-- Use this part # for 1.x, 2.x, 3.x, 4.x and HiSpeed QXi Systems Part Type: GP CONSUMABLES Part Weight: 25.00 LBR Repairable: No Returnable: No Hazardous Material: N Description: COVER ASSEMBLY TABLE TOP - RIGHT FRU: Yes Status: Orderable Comments: FLS - COVER ASSEMBLY TABLE TOP-RIGHTU/O LIGHTSPEED & PET TABLE 6/30/99 MS08992 THIS REPLACED THE 2149735 PER CHRIS DOERING MSA1248 10/99 GPC TABLE MOVED TO CHINA 5/24/01 NOW ASIA SOURCED THIS P/N HAS BEEN REPLACED BY P/N 2372372 (ONLY APPLICABLE ON HPOWER SYSTEMS) PER PCN 220864. MS20544 3/31/03. DIMS: 90" LONG; 70" WIDE FLS - PLEASE CONVERT SPH ORDER TO OVERNIGHT SHIPMENT IF PART AVAILABLE IN MEMPHIS AND IF FEDEX SERVICE (INCLUDING 8:00 AM SERVICE) MEETS FE NEED TIME CRITERIA
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required