Pular para o conteúdo principal
GE Healthcare · CTHiSpeedLightSpeed182614182607

HiSpeed QX/i - Octane

Symptom

System would not scan and prescribed tilt light remained flashing even though gantry display showed that the gantry was at the correct position.

Error message

Error: 182614 Tilt drive is not stopping within 1500 msec. Expected stopping position XX (.01 deg) Current position YY (.01 deg). See Long Description for error details and example Host: ETC Process: Tilt File: tmcShutDown.c 1.31 1/29/93 Line: 121 Function: PATIENT ANATOMY POSITIONING : Elevation - Tilt Scan: 5478/4/0 Type: None/Unknown Exception Level: Pri/Soft Time: 16:25:56:115 Log Series: 151 HW/SW error: Tilt drive is NOT stopping within 1500 msec. Expected Stopping Position -50 (.01 deg). Current Position -23 (.01 deg). Tilt Direction: 0 (0 = BCK 1 = FWD). Error: 182607 Host: ETC Process: Tilt File: CmdMotion.c 1.21 2/17/95 Line: 139 Function: PATIENT ANATOMY POSITIONING : Elevation - Tilt Scan: 7839/2/0 Type: None/Unknown Exception Level: Pri/Soft Time: 12:12:01:160 Log Series: 617 HW/SW error: Velocity tracking error. Actual Velocity 0 (.01 deg/sec) Expected Velocity 100 (.01 deg/sec) Tol 80 (.01 deg/sec) Cur Pos -2181 (.01 deg) Tilt Dir: 1 (0 = BCK 1 = FWD). INFO: Probable Problem could be 180V Power is LOW.

Applies to

Models
HiSpeed, LightSpeed
Product
HiSpeed QX/i - Octane Always MDAS4 101I.2_HSQXIM5 101.4_HSQXIM4 HiSpeed QX/i - Octane Method of visual identification Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config List of Supported Console Types Octane with Pegasus Recon hardware. List of softwares the product can run 101I.2_HSQXIM5 101.4_HSQXIM4 - obsolete FAQ's Table weight limit - Up to 400 lb. (180 kg) with ± .25 mm positional accuracy. 450Ib (205 kg) max weight Tube type - D3186T Current production details - See Technical Reference Manual found on the Common Document Library Tips and workarounds, where to find it - Common Document Library(CDL) . Search for the latest FMI software release. In the furnished materials will be the list of various manuals with part numbers for the various languages. Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required

Related GE Healthcare CT issues