GE Healthcare · CTHiSpeed2601181775005450148
Scanner failed to initiate scan
Symptom
Scanner failed to initiate scan
Error message
Error: 260118177 Jedi (40-0114)Rotor not at speed. See Long Description for complete error Thu Feb 15 14:07:54 2007 260118177 4 orp orp_subsys gen_exec.c 2376 Thu Feb 15 14:07:54 2007 Host : Jedi Ermes # : 260118177 Exception Class : Abort Severity : Primary File : gen_exec.c Line# : 2376 Function : No System Function Reported Scan Type : Static Scan: 50054/1/1 (40-0114) Rotor not at speed . Z6,Z7= 2h,0h Mon Apr 17 14:01:27 2006 Error: 260118177 Host: orp Process: orp_subsys File: gen_exec.c Line: 2150 Mon Apr 17 14:01:26 2006 Host : Jedi Ermes # : 260118177 Exception Class : Abort Severity : Primary File : gen_exec.c Line# : 2150 Function : No System Function Reported Scan Type : Static Scan: 50148/1/1 (40-0114)Rotor not at speed. ^C Z6,Z7= 2h,0h
Applies to
- Models
- HiSpeed
- Product
- HiSpeed YMS Series HiSpeed Series DXi, FXi, LXi, ZXI, and NXI Including Single / Twin detector and Glass / Metal Tubes. See Long Description for Details Subsystem/Components DXI (NP) FXI,LXI (NP+) ZXI (NP++ NXI (NP+ Twin NXI (NP++ Twin OC O2 running Unix or upgraded to Linux PC Gantry Alighnment Lights Halogen Laser Laser Laser Laser Mechanics Common Electronics firmware is different twin Det/Das Twin Det/DAS Table IMS no Yes Yes Yes Yes Generator Jedi Jedi NP++ Jedi Jedi NP++ Jedi Tube D3142T D3142T D3152T D3142T D3152T PDU Common Options List for V/R 5.5, 6, 7, 9, and 10 System 3D Power 440ma Max Image Disk 20000 Smart Prep Fast Scam 0.7 sec Performix 530 cooling Smart Recon Fast Scan 0.8 sec Asymmetric Scan SmartView Fast Scan 1.0 sec Cardiac gating DemtaScan Helical 30 Max Smart Addition Navigator Helical 60 Max Respiratory Gating Helical Plus Helical 120 Max Reformat Cpmmect {rp Raw Data 1000 max VolumeRendering2 ImageDosk Remote Tilt CT Colono Pioneer Mod Enhanced Cooling The following Options name changes Option (V5.5x,V6.0x,V7.x,V9.x,V10x) Option (V8.1x and V11.x) 3D >> Volume Analysis2 Navigator >> Navigator2,VolumeRendering2,VolumeAnalysis2 CtPerfusion >> CTPersusion2 Reformat >> Functool Options V8.1x and V11.x VolumeAnalysis2 Power 440ma ImageDisk 2000 Helical Plus Smart Prep Fast Scan 0.7 sec Performix 530 cooling Connect Pro Smart Recon Fast Scan 0.8 sec Asymmetric Scan ImageDisk SmartView Fast Scan 1.0 sec Cardiac Gating Pioneer MOD* DentaScan Helical 30 Smart Addition Power 200 ma max Navigator2/VolumeRendering2/ VolumeAnalysis Helical 60 Respiratory Gating Power 250 ma Max Power 300 ma Max Helical 120 Thickness 0.5mm CTColon Power 350 ma Max Raw data 1000 CtPerfusion2 AdvVesselAnalysis Remote Tilt Extended FOV Functool Enhance Cooling Performix Tube VolumeRendering2
- Component
- 2241313-2 P9230TG High Voltage Anode cable. Used on HiSpeed Series with performix tube. Do NOT use this cable for HP 60! Please read the Long Description 2241313-2 P9230TG High Voltage Anode cable. Used on HiSpeed Series. This cable has also been used for the Cathode Side - it is a little longer and matches the anode cable length better. Do NOT use this cable for HP 60! HP60 needs 5128609 for Anode HV Cable Part #: 2241313-2 Part Type: GP CONSUMABLES Part Weight: 0.00 LBR Repairable: No Returnable: No Hazardous Material: N Description: P9230TG HV CABLE FRU: Yes Status: Orderable Comments: FLS - P9230TG HV CABLE USED ON: CT NP, EBISU HIGHSPEED NX/I ADDED PER SPCN: CT-10109NP MS13452 030838 RISK: FUNCTIONALITY FREQUENCY: LOW
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.