Pular para o conteúdo principal
GE Healthcare · CTHiSpeed

CT/e Dual, CT ProSpeed AII/FII Irix or Linux

Symptom

How do I change the date or the time? How do I change the date or the time ?

Applies to

Models
HiSpeed
Product
CT/e Dual, CT ProSpeed AII/FII Irix or Linux HiSpeed CT/e Dual CT Scanner System see long Description for sales information Product Name: CT/e Dual CT Scanner System Irix A list of types. (a Product/hardware table) N/A An On-site / Remote identification aid . (Example: check_config) N/A A Table of options (included, optional, new introductions, …) N/A A list of Software that has run on this product (Product / Software Compatibility Table) N/A Product photographs N/A Marketing Information N/A Documents: Always use the most appropriate documentation for your system. Documentation can be found on CT Service CDROM/DVD, or online at FCT Service Engineering Tech Pubs Website, Common Document Library, and My Workshop. Links: Drawing Print 2320306-2CCT : http://gemspdm.med.ge.com/ematrix/common/eLibDocument.jsp?type=type_DrawingPrint&name=2320306-2CCT&rev=9 Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Software
4.01, 4.02 , 4.03 , 4.04 , 4.05 , 4.06 , 4.07 Software used on CT/e Dual, ProSpeed AII/FII Series See LD for more info 4.01, 4.02, 4.03, 4.04 , 4.06 Software used on CT/e Dual, ProSpeed AII/FII Series 4.01 was released as FMI No: 22814 and upgraded V/R 3.64 or earlier to V/R 4.01 FMI 22814 Kit (5135601) includes: Item Qty Description Part # 1 1 FMI 22814 Instruction (This Document) 5135602 2 1 CT/e Twin Linux V/R 4.01 Customer Letter 5128954 3 1 CT/e Twin Linux Service Manual Class A CD-ROM 2337938 4 1 ProSpeed (II), CT/e (Dual) Xtreme Series Core OS 5126711 5 1 ProSpeed II, CT/e Dual Xtreme Series Application Software V/R 4.0 5126713 6 1 ProSpeed II, Xtreme Patch V/R 4.01 5128444 7 1 Label of Software Assy V/R 4.01 for FMI 22814 5135607 4.02 was never released to the field 4.03 was released with Service Note GEHW-SN110602A P/N: 5161319 : ProSpeed II, CTE Dual Xtreme Series Patch V4.03)can be ordered 4.04 was released with Service Note GEHW-SN110606A P/N: 51786631. Note: The CD-Rom only includes this patch. Previous patches are not included. Note: The Class M Version will not be changed after the patch installed. ____________________________________________________________________________ Patch 4.05 Service Note GEHW-SN110615B P/N 5193587 V/R 4.05 Software Fixed Bug List Exam number jump 1 sometimes,Unable to move "Image Filter Window", A number shifts to the right. (Film Image and Save Screen Image) Refer to appendix, ScreenSave of color image made by VolumeRendering can't be transferred to radworks., "PrintSeries" window characters too small., media filed display error note after saving the exam by exam ______________________________________________________________________________ Patch 4.06 Service Note GEHW-SN110707A P/N 5257021 IMPPROVEMENT Special requirement of third party server (TechMatrix) on the TAG(0020, 0012)in CT reformat image.(PQR13079634). When wrong click "shift+enter" keyboard in TextField by customer, such as Patient ID, Patient Name, the dotted square is shown as the part of the input.( PQR 13104841). Update Service Diagnostic Tools for DBPCI2 phase in. Update DBPCI2 driver for DBPCI2 phase in. BUGFIX Following anomaly have been resolved with patch V/R 4.06 If the first scan completed with the same value of location start/end. [One More] selected, sometime it will cause UI freeze.( PSR 13101988) Protocol generated an invalid value that the "NextProtocol" value is wrong in the Batch Film Protocol, which caused Reformat into an endless loop and system speed become very slow .(PQR 13099033). Scanrx crash when create a new scout series and select scout type & select [create before] many times. (SPR: GEBct04533).
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required

Related GE Healthcare CT issues