LightSpeed 3.X (Ultra, Plus, QXi) - GOC2

Symptom

Applications software fails to boot up completely and automatically shuts itself back down. Applications software fails to boot up completely and automatically shuts itself back down

Error message

Error: 200108008 You will not be able to scan because no calibration information is available See the long description for the full error code Thu Jun 9 08:19:31 2005 Error: 200108008 Host: pmct Process: scanRx File: SIRx.cxx Line: 1307 Function: Data Acquisition: OC Processing Failed to get Calibration status. You will not be able to scan because no calibration information is available. Try pressing End Exam followed by New Patient . This will cause ScanRx to attempt to read the calibration database again

Error: 200002352 A HOST_SHUTDOWN was initiated by the death of scanmgr See Long Description for full error Tue Nov 23 17:26:47 2004 Error: 200002352 Host: srct Process: cupMonitor File: ssProcStop.c Line: 1065 A HOST_SHUTDOWN was initiated by the death of scanmgr With 06MW03.X software this is listed as: Fri Oct 6 19:02:31 2006 Error: 200002352 Host: dominct Process: cupMonitor File: ssProcStop.c Line: 766 A HOST_SHUTDOWN was initiatied by the unexpected termination of scanmgr.

Error: 200108051 An error had been detected while calling getAnd CheckCals function. see LD for full error Sun Oct 23 08:42:11 2005 Error: 200108051 Host: emc-ct1 Process: scanRx File: SIRx.cxx Line: 265

Applies to

Models
LightSpeed
Product
LightSpeed 3.X (Ultra, Plus, QX/i) - GOC2 This is HP CPU host running LINUX with Pegasus IG. 308L.8_H3.3M4 ~ 4 or 8 slice MDAS. ~ Could be an Ultra, Plus or QXi system. Must run swokinstall -p to verify. ~ See Long description for details . LightSpeed 3.X MDAS4 Gantry and GOC2 Gantry - 2281177-2, DAS - 2272768, Console – 2341104-2, Table - 2276776, PDU - 2269902 Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Software
308L.8_H3.3M4 for LightSpeed 3.X (Ultra, Plus, QX/I with Console GOC2 (w/Linux PC) Assembly (2315653) or Xtream (GRE) Console - showprods returns 308L.8_H3.3M4 for LightSpeed 3.X (Ultra, Plus, QX/I with Console GOC2 (w/Linux PC) Assembly (2315653) or Xtream (GRE) Console - showprods returns 308L.8_H3.3M4 for LightSpeed 3.X (Ultra, Plus, QX/I with Console GOC2 (w/Linux PC) Assembly (2315653) or Xtream (GRE) Console
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.