Symptom

Intermittent system lock ups when system is idle or scanning or sometimes does not boot up. with no errors in log

Applies to

Models
HiSpeed
Product
CT/e Dual, CT ProSpeed AII/FII Irix or Linux HiSpeed CT/e Dual CT Scanner System see long Description for sales information Product Name: CT/e Dual CT Scanner System Irix A list of types. (a Product/hardware table) N/A An On-site / Remote identification aid . (Example: check_config) N/A A Table of options (included, optional, new introductions, …) N/A A list of Software that has run on this product (Product / Software Compatibility Table) N/A Product photographs N/A Marketing Information N/A Documents: Always use the most appropriate documentation for your system. Documentation can be found on CT Service CDROM/DVD, or online at FCT Service Engineering Tech Pubs Website, Common Document Library, and My Workshop. Links: Drawing Print 2320306-2CCT : http://gemspdm.med.ge.com/ematrix/common/eLibDocument.jsp?type=type_DrawingPrint&name=2320306-2CCT&rev=9 Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Component
2204421 SYSTEM MODULE O2 USED ON LXI, FXI, DXI NP NP+ and QXi See LD for more information 2204421 SYSTEM MODULE O2 Part #: 2204421 Part Type: GP REPAIRABLES Part Weight: 2.27 LBR Repairable: Yes Returnable: Yes Hazardous Material: N Description: P9231VK SYSTEM BOARD FRU: Yes Comments: FLS - SYSTEM MODULE O2 USED ON LXI, FXI, DXI NP NP+ OLD #2181101-4 ALL GONE! ALSO USED ON QXI SYSTEMS SYSTEM BOARD VENDOR - SGI NEW REVISION = 013-2430-002 BK 11-28-00 ********************************************************** USE UP 2181101-4;THE PART WILLBE CARRIED UNDER 2204421 # QUESTIONS CALL GWENN 548-2825 10/2/98 VC - 627584 = SGI BROOKFIELD, WI., 3/29/02- C2R COMPLETE. SHIP AS T3202LD. MS12464 SYSTEM MODULE U/O HISPEED-YMS M3 FW20'98 MS1101 3/98 GELS - "SYSTEM BOARD ASM O2 USED ON LXI, FXI, DXI NP NP+ FP 99/04 IF NO STOCK, SEE # 2181101-4 WICH IS LOCALLY PURCHASED BY AM",SYSTEM MODULE Repair Operations Service note for the 2204421 O2 system board 95%of all DOA’s come back because of no power up, no video, or unit dead, and are No Defect Foundat the Repair Supplier. When you replace the 2204421or any other part in the O2 Chassis: Cycle the reset or power button on the O2 Chassis when you power on or off the console.
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required

Related GE Healthcare CT issues