Octane computer will not boot
Symptom
Message says, “Running power-on diagnostics…” that message goes away and the system hangs displaying the screen that says “Octane”. See Long Description for more details Message says, “Running power-on diagnostics…” that message goes away and the system hangs displaying the screen that says “Octane”. Octane computer will not boot. When console is turned on the monitors turn on and there is a message that says, “Running power-on diagnostics…” that message goes away and the system hangs displaying the screen that says “Octane”.
Applies to
- Models
- LightSpeed
- Product
- LightSpeed 3.X (Ultra, Plus, QX/i) - Octane Always 4 or 8 slice MDAS 308i.2_H3.1M5 LightSpeed 3.X - Octane Method of visual identification Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config List of Supported Console Types Octane with Pegasus Recon hardware. List of softwares the product can run 308I.2_H3.1M5 305.4_H3.1M4 - obsolete 303.1_H3M4 - obsolete FAQ's Table weight limit - Up to 400 lb. (180 kg) with ± .25 mm positional accuracy. 450Ib (205 kg) max weight Tube type - D3186T Current production details - See Technical Reference Manual found on the Common Document Library Tips and workarounds, where to find it - Common Document Library(CDL) . Search for the latest FMI software release. In the furnished materials will be the list of various manuals with part numbers for the various languages. Example: English versions 2211223-100 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Component
- 2169940-53 OCTANE PCI CHASSIS See the LD for FEMC part comments 2169940-53 OCTANE PCI CHASSIS Part #: 2169940-53 Part Type: GP REPAIRABLES Part Weight: 2.73 LBR Repairable: Yes Returnable: Yes Hazardous Material: N Description: OCTANE PCI CHASSIS FRU: Yes Status: Orderable FLS - OCTANE 1 AND 2 PCI CHASSIS. PART MAY BE AVAILABLE AS A UU PART. THIS PART IS THE SAME PART AS 2169940-7; HOWEVER, IT IS SOURCED FROM A DIFFERENT SECTION OF SGI THAN THE MFG VERSION. 10/01-COMPONENT COLLECTION AT RDC 5/23/02- C2R COMPLETED. SHIP AS T3202LE. 03F03FW48 - T3202LE REPLACED BY T3202PE T3202EQ is the PCI Chassis with Boards.
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required