Pular para o conteúdo principal
GE Healthcare · CTLightSpeed200001808200002352

LightSpeed 5.X (80/100kW)

Symptom

Clicking End Exam shuts down CT See Long Description for Details. Clicking End Exam shuts down CT with Error: 210000454 Info: database checkpoint was performed for exam 748 Error: 200002352 A HOST_SHUTDOWN was initiatied by the death of scanRx Error: 200001808 Ecomm internal error detected (internal database error) The customer originally complained that the system shutdown when they moved the table (getting the patient off), but after troubleshooting it was found that every time End Exam is clicked the system would shut itself down. They just happen to be hitting End Exam right before they went to take the patient off the table. Below is the error string. Mon Nov 28 10:52:25 2005 Error: 200109110 Host: kmcct2 Process: scanRx File: UIRx.cxx Line: 9857 Function: Data Acquisition : OC Processing End: Prospective Exam: 748 : Protocol: 1.1 Series: 1 : Scans: 1 : Images: 1 (Scout) Series: 2 : Scans: 15 : Images: 30 : PMRSeries(0) Mon Nov 28 10:52:25 2005 Error: 210000454 Host: kmcct2 Process: dms File: Initialize.cxx Line: 913 Info: database checkpoint was performed for exam 748. Mon Nov 28 10:52:30 2005 Error: 200002352 Host: kmcct2 Process: cupMonitor File: ssProcStop.c Line: 1065 A HOST_SHUTDOWN was initiatied by the death of scanRx. Mon Nov 28 10:52:30 2005 Error: 200001808 Host: kmcct2 Process: graphicRx File: ecommL_callback.c Line: 107 Ecomm internal error detected (internal database error).

Error message

Error: 200001808 Ecomm internal error detected (internal database error). See LD for complete error Mon Nov 28 10:52:30 2005 Error: 200001808 Host: kmcct2 Process: graphicRx File: ecommL_callback.c Line: 107 Ecomm internal error detected (internal database error).

Error: 200002352 A HOST_SHUTDOWN was initiatied by the unexpected termination of scanRx. See long description for complete error Error: Fri Jan 19 16:02:31 2007 Error: 200002352 Host: act8 Process: cupMonitor File: ssProcStop.c Line: 766 A HOST_SHUTDOWN was initiatied by the unexpected termination of scanRx. Mon Nov 28 10:52:30 2005 Error: 200002352 Host: kmcct2 Process: cupMonitor File: ssProcStop.c Line: 1065 A HOST_SHUTDOWN was initiatied by the death of scanRx.

Applies to

Models
LightSpeed
Product
LightSpeed 5.X (80/100kW) LightSpeed 5.X (80/100kW) ~ Use with both MDAS and GDAS ~ GRE Console HP_H_G16 HP_H_M16 HP_O_M16 LightSpeed 5.X (100kW) GDAS16 with GRE Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Software
05MW14.5 for all systems with GRE/Xtream consoles on HiSpeed QX/i and LightSpeed 1.X, 2.X, 3.X, 4.X, 5.X Series(QXi, PLUS, ULTRA, LS16, PRO 16, RT). Obsoleted by FMI 25365 deploy FMI 25365 It is the Service person's responsibility to use the appropriate documentation when performing and verifying service. Refer to FMI 25365: 06MW03.5 SW Update for CT-LS 1X/2X/3X/4 DIR 5161945-100, which can be found on the Distributed Technical CDROM/DVD, or online Links to any needed documentation is found in the Product concepts as an attachment called "ProductDocumentLinks"
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required

Related GE Healthcare CT issues