GE Healthcare · CTLightSpeed
LightSpeed 5.X (80/100kW)
Symptom
System will not boot-up to application - Getting pink box Warning message "StartMon process is already running. Request rejected." See long description for details System will not boot-up to application - Getting pink box Warning message "StartMon process is already running. Request rejected.
Error message
startMon already running seen in SYSLOG (or messages) See the Long Description for the full error and command to find error startup: startMon: startMon already running Type cd /usr/adm (or /var/log) Type more SYSLOG (or messages) Look for current time and date /Dec 22 Dec 22 07:06:14 5B:ampct startup: startMon: startMon already running
Applies to
- Models
- LightSpeed
- Product
- LightSpeed 5.X (80/100kW) LightSpeed 5.X (80/100kW) ~ Use with both MDAS and GDAS ~ GRE Console HP_H_G16 HP_H_M16 HP_O_M16 LightSpeed 5.X (100kW) GDAS16 with GRE Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Software
- 04MW44.9 for all LightSpeed systems with GRE/Xtream consoles (QXi, PLUS, ULTRA, LS16, PRO 16, RT)(1.X, 2.X, 3.X, 4.X, 5.X) Open Long Description for details. 04MW44.9 for all LightSpeed systems with GRE/Xtream consoles (QXi, PLUS, ULTRA, LS16, PRO 16, RT)(1.X, 2.X, 3.X, 4.X, 5.X) 04MW44.9A signifies Patch A has been loaded on a HP60 system. Class C Class M Application Software Set CD Part No. Ver. CD Label CD Part No. Ver. CD Label Set Part No. Apps. CD Part No Apps. CD Label showprods/ Service Desktop Intro. Date Comment 5135965 Supports Software 04MW44.9 on GRE/Xtream Class C For use on GRE/Xtream consoles on LightSpeed 5X Series H-Power 60/80/100 and MDAS-RT 5135966 Supports Software 04MW44.9 on GRE/Xtream Class M For use on GRE/Xtream consoles on LightSpeed 5X Series H-Power 60/80/100 and 5X MDAS-RT 5135967 5135962 Applications Disk 1 5135963 Applications Disk 2 5135964 DARC Applications Disk 2399296 Operating System, Ver 1.7.10 Disk 2399297 Serial Over LAN Disk 04MW44.9 May 2005 FMI 25351 For HP100, HP80, and RT Only The GRE Common Applications software supports multiple hardware configurations via a single software set. The new software version string has the following format: <software_label>.<G>_<T>_<D>_<R> The "software label" format is: YYLWxx.ZZ Where: YY = Year. For example 04. L = Location. M - Milwaukee, H - Hino, B - Beijing. Wxx = Fiscal Week. For example, W15. ZZ = Revision number for each build/reroll. Refer to Table B for an explanation of the <G>_<T>_<D>_<R> format. Table B Common Applications Sotware Naming Convention G = GANTRY TYPE T = TUBE TYPE D = DAS TYPE R = RECON HW TYPE H1 = LightSpeed 1.X P = Performix S4 = SDAS4 P = Pegasus H2 = LightSpeed 2.X, 3.X, 4.X O = OEM M4 = MDAS4 G = GRE HP = LightSpeed 5.X H = Hercules M8 = MDAS8 WB = LightSpeed 5.x RT M16 = MDAS16 QX = HighSpeed QXi G16 = GDAS16 The variables G, T, D, and R are generated dynamically based on the type of hardware configuration this software is installed on. The information for the dynamic part of the string is obtained from the INFO files which are located in /usr/g/config directory. An example string based on the above format is as follows: 04MW13.7.H2_P_M4_G The break down is as follows: This is 2004 software release at Milwaukee in Fiscal Week 13 with a revision number "7". The hardware configuration is "H2" gantry with "Performix" tube, "MDAS4", and "GRE" recon hardware. CDL Links: DIRECTION 2378261-100 GRE SOFTWARE INSTALLATION PROCEDURES Direction 2407441-100 Common Platform Q4 2004 Release Application Tips and Work-Arounds
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required