GE Healthcare · CTLightSpeed260125037244633260125003260115190

LightSpeed 5.X (60kW)

Symptom

When trying to move cradle in or out of the gantry, it moves about ½ an inch and then stops. See long description for details. The table will move up and down. When trying to move cradle it or out of the gantry, the cradle moves about ½ an inch and then stops.

Error message

Error: 260125037 Table is in shutdown state, cycling power for the table See the LD for the complete error code Error: 260125037 Table is in shutdown state, cycling power for the table Wed May 25 17:35:00 2005 Error: 260125037 Host: tgp Process: tgp_subsys File: ta_func.c Line: 451 Wed May 25 17:35:00 2005 Host : Table Gantry Processor Ermes # : 260125037 Exception Class : Soft Severity : Pri/Soft File : ta_func.c Line# : 451 Function : SYSTEM COMMUNICATIONS : Table Communications Scan Type : None/Unknown Scan: 0/0/0 Table is in shutdown state, cycling power for the table

Error: 244633 Table reports that Table Communication becomes down. Wed May 25 17:35:00 2005 Error: 244633 Host: ct01 Process: fwmgr File: fwmgr_events.c Line: 7301 Function: No system function reported Scan Type: Not scanning Scan: 0/0/0 Scan Seq Id: 0 Table reports that Table Communication becomes down.

Error: 260125003 Table Communication has been established. Fri May 20 15:14:49 2005 Error: 260125003 Host: tgp Process: tgp_subsys File: ta_func.c Line: 246 Fri May 20 15:14:34 2005 Host : Table Gantry Processor Ermes # : 260125003 Exception Class : Soft Severity : Pri/Soft File : ta_func.c Line# : 246 Function 

Applies to

Models
LightSpeed
Product
LightSpeed 5.X (60kW) LightSpeed 5.X (60kW) ~ Use with MDAS or GDAS HP_P_G4 HP_P_G8 HP_P_G16 HP_P_M16 LightSpeed 5.X 60KW G-DAS16 with GRE Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Component
2342727-4 : 5.X Cradle encoder. This part replaces the 2342727-3 and 2342727-2 This is an absolute position encoder with no pot. See long description for details Displaying Change-Up Data: Part "2342727-2" and "2342727-3" changed to 2342727-4 Part #: 2342727-4 Part Type: GP CONSUMABLES Part Weight: 0.00 LBR Repairable: No Returnable: No Hazardous Material: N Description: FRABA OCD H-Power String Encoder FRU: Yes Status: Orderable Comments: Added by ecr: 2020264. Please continue to use stock of 2342727-3, until depleted. -3 and -4 are mfg alts of one another. ms13452 Revised per to Asset confirmation Comments: Added per ECR2011883 to replaced the 2342727-2 The 5.x table design incorporates Absolute encoders used for cradle and elevation, instead of incremental encoders. The absolute encoder has the capability to generate a unique binary 'word' for each encoder shaft position, allowing the encoder to provide positional information instantly upon power-up, unlike incremental encoders. Therefore, potentiometers are NOT needed for cradle or elevation encoder circuits.
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.