GE Healthcare · CTLightSpeed26011821310153
LightSpeed 5.X (80/100kW)
Symptom
Scanner Hardware Fault with high voltage spits. Scanner Hardware Fault with high voltage spits
Error message
Error: 260118213 (60-0316) Spit Max error. PPC board has detected the number of tube spits during exposure has reached the limit See Long Description for two error examples Sat Dec 17 18:32:18 2005 Error: 260118213 Host: orp Process: orp_subsys File: gen_exec.c Line: 2150 Sat Dec 17 18:32:17 2005 Host : Jedi Ermes # : 260118213 Exception Class : Abort Severity : Primary File : gen_exec.c Line# : 2150 Function : No System Function Reported Scan Type : Axial Scan: 10153/2/2 (60-0316)Spit Max error. PPC board has detected the number of tube spits during exposure has reached the limit (see theory of operation, software section).^C Z6,Z7= ch,0h
Applies to
- Models
- LightSpeed
- Product
- LightSpeed 5.X (80/100kW) LightSpeed 5.X (80/100kW) ~ Use with both MDAS and GDAS ~ GRE Console HP_H_G16 HP_H_M16 HP_O_M16 LightSpeed 5.X (100kW) GDAS16 with GRE Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Component
- D3192T Performix Pro Tube, now replaced by D3194T (READ PARTS COMMENTS ) See Long description for details Part #: D3192T ( now replaced by the D3194T tube) Part Type: GP TUBES Part Weight: 0.00 LBR Repairable: No Returnable: Yes Hazardous Material: N Description: HERCULES X-RAY TUBE UNIT (RED) FRU: Yes Status: Orderable Comments: FE ASSIST MS6588 10/30/2003 D3192T = H16 PRO TUBE/ HP100. NOTE TO FES AND DCOS TEAM: IF SELLING TO AN END USER AND NOT INSTALLED BY A GE FE, AN END USER CERTIFICATION LETTER MUST BE SIGNED BY THE CUSTOMER. UPON RECEIPT OF SIGNED LETTER, ORDER CAN BE PLACED. **TO OBTAIN COPY OF CERT. LTR. CONTACT DCOS TEAM AT 800-558-2040 OPTION 2. **ANY QUESTIONS, CONTACT LYNN WESTBROOK OR ROD MCCRIMMON. ******* *** 2ND OPINION NOTES *** Part is no longer available. VCT, Pro100 and RT16 systems use D3194T as replacement. D3194T tubes now manufactured have a high voltage cable one inch longer. Longer cable is necessary for use in all Wide Bore Gantries. If a very old D3194T tube is installed on a Wide Bore Gantry, the high voltage cable may be too short. A newer D3194T tube would have to be ordered in this case. With the release of M4 software, 07BW08.3.WB_H_G16_GTM, the correct tube to order is now D3194T for RT16 Systems . M4 software releasing to pilot and clincal sites with FMI 22915. - P Quilter June 23, 2007.
- Area
- CT