GE Healthcare · CT
Lightspeed 1.X - Octane
Symptom
Software fails to boot with XIO Slot Reset Failure message on the screen. See the Long description for the full error code. Software fails to boot with XIO Slot Reset Failure message on the screen Error found in /usr/adm/SYSLOG Dec 14 11:44:52 6B:ct01 flash: 12/14/2005 16:42:36.000 GMT: XIO Slot Reset Failure *FAILED*
Error message
XIO Slot Reset Failure seen in /usr/adm/SYSLOG See Long Description for the full error code XIO Slot Reset Failure Type cd /usr/adm to see the boot logs Type more SYSLOG to see the errors. Dec 14 11:44:52 6B:ct01 flash: 12/14/2005 16:42:36.000 GMT: XIO Slot Reset Failure *FAILED*
Applies to
- Product
- Lightspeed 1.X - Octane 10.5_2.8.2I_H1.3M4 10.4.1_2.8.2I_H1.3M4 - obsolete Lightspeed 1.X - Octane Method of visual identification Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config showprods|grep Apps note: if check_config does not work then the software is not up to date with all FMI's. Check FMI history and verify that all patches have been loaded since last software reload. Ref FMI 25269 List of Supported Console Types Octane with Pegasus Recon hardware. may have an 02 SBC - Run df -k to see if the sbc is partitioned. List of softwares the product can run 10.5_2.8.2I_H1.3M4 10.4.1_2.8.2I_H1.3M4 - obsolete FAQ's Table weight limit - Up to 400 lb. (180 kg) with ± .25 mm positional accuracy. 450Ib (205 kg) max weight Tube type - D3176T Current production details - See Technical Reference Manual found on the Common Document Library Tips and workarounds, where to find it - Common Document Library(CDL) . Search for the latest FMI software release. In the furnished materials will be the list of various manuals with part numbers for the various languages. Example: English versions 2211223-100 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Component
- 2169940-53 OCTANE PCI CHASSIS See the LD for FEMC part comments 2169940-53 OCTANE PCI CHASSIS Part #: 2169940-53 Part Type: GP REPAIRABLES Part Weight: 2.73 LBR Repairable: Yes Returnable: Yes Hazardous Material: N Description: OCTANE PCI CHASSIS FRU: Yes Status: Orderable FLS - OCTANE 1 AND 2 PCI CHASSIS. PART MAY BE AVAILABLE AS A UU PART. THIS PART IS THE SAME PART AS 2169940-7; HOWEVER, IT IS SOURCED FROM A DIFFERENT SECTION OF SGI THAN THE MFG VERSION. 10/01-COMPONENT COLLECTION AT RDC 5/23/02- C2R COMPLETED. SHIP AS T3202LE. 03F03FW48 - T3202LE REPLACED BY T3202PE T3202EQ is the PCI Chassis with Boards.
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.