GE Healthcare · CT18415424658
Lightspeed 1.X - Octane
Symptom
Scanner Hardware Stopped Scan. Scanner Hardware Stopped Scan
Error message
Error: 184154 STC reports Timeout on Exposure Command to X-ray On See LD for complete error Tue Apr 26 12:32:20 2005 Error: 184154 Host: STC Process: Scan Control File: scTrigSeqActions.c 1.65 Line: 1349 Function: XRAY GENERATION : Final Exposure Command Scan: 24658/2/28 Type: Axial Exception Level: Pri/Most Severe Time: 12:32:20:370 Log Series: 206 Timeout on Exposure Command to X-ray On. HW Error: Possible hardware problem. Timeout is: 300 mS.
Applies to
- Product
- Lightspeed 1.X - Octane 10.5_2.8.2I_H1.3M4 10.4.1_2.8.2I_H1.3M4 - obsolete Lightspeed 1.X - Octane Method of visual identification Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config showprods|grep Apps note: if check_config does not work then the software is not up to date with all FMI's. Check FMI history and verify that all patches have been loaded since last software reload. Ref FMI 25269 List of Supported Console Types Octane with Pegasus Recon hardware. may have an 02 SBC - Run df -k to see if the sbc is partitioned. List of softwares the product can run 10.5_2.8.2I_H1.3M4 10.4.1_2.8.2I_H1.3M4 - obsolete FAQ's Table weight limit - Up to 400 lb. (180 kg) with ± .25 mm positional accuracy. 450Ib (205 kg) max weight Tube type - D3176T Current production details - See Technical Reference Manual found on the Common Document Library Tips and workarounds, where to find it - Common Document Library(CDL) . Search for the latest FMI software release. In the furnished materials will be the list of various manuals with part numbers for the various languages. Example: English versions 2211223-100 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Component
- 46-296317P3 XENTEK POWER SUPPLY See Long Description for more information including stc and ETC power supply locations Part #: 46-296317P3 Part Type: GP CONSUMABLE - RETURNABLE Part Weight: 0.00 LBR Repairable: No Returnable: Yes Hazardous Material: N Description: POWER SUPPLY FRU: Yes Status: Orderable Exchange: Not Available Comments: FLS - XENTEK POWER SUPPLY U/O GANTRY & TABLE CTI AND GENESIS AND HORIZON USE P3'S ON CTI ONLY 10/31/96 MS08992 GVR ---------------------------------------------------------- 46-296317P3 REPLACED T3202GT /46-296317P2 PER PCN 189892. MS4636 12/2/96 ---------------------------------------------------------- ALSO USED ON QXI LIGHTSPEED TO BRASIL: IF NO STOCK, CHANGEORDER TO T3202JR. COLLECTION OF DEFECTIVES START7/23/01 MS5277 TAIYO YUDEN P/N 8230 +5VDC, +15VDC, -15VDC, +24VDC,IN 120VAC, 3.6A 50/60HZ MS5900 WAS T3202JR FLS - PLEASE CONVERT SPH ORDER TO OVERNIGHT SHIPMENT IF PART AVAILABLE IN MEMPHIS AND IF FEDEX SERVICE (INCLUDING 8:00 AM SERVICE) MEETS FE NEED TIME CRITERIA FE ASSIST: IN ORDER TO INCREASE REVENUE GLOBAL PARTS HAS CREATED A PROGRAM TO HARVEST PARTS FROM RENEWABLE RESOURCES. THESE PARTS OFFER DIRECT SAVINGS TO THE BUSINESSAND THE FIELD. ORDER THE "U" PART IF AVAILABLE. IF NO "U" USED PARTS ARE AVAILABLE CARES WILL CHANGE THE ORDER TOA NEW PART.
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required