Symptom

Fastcals failed to complete. Fastcals failed to complete

Error message

Error: 230015013 Failure opening a file for reading in the Cal Database. See LD for complete error Tue Sep 20 2005 08:36:512005 Error:230015013 Host: ls16 Process:scanmgr File: cal_db_file_io.c Line: 226 Function: CAL Processing : SBC Processing Failure opening a file for reading in the Cal Database. File:usr/g/cal_db/kv120/large_sfov/16x0625/large_spot/dasgain5/cal.1.sin

Error: 230015022 Failure loading matrix decon kernel fields in cal module header. See Long Description for complete error Tue Oct 18 07:20:43 2005 Error: 230015022 Host: ctls3 Process: scanmgr File: cal_db_funcs.c Line: 264 Function: CAL Processing : SBC Processing Failure loading matrix decon kernel fields in cal module header. File: /usr/g/cal_db/misc/decon/4x125/cal.large_sfov.1.md

Error: 230015024 A corrupt file has been found in the cal database See LD for complete error Tue Sep 20 08:36:51 2005 Error: 230015024 Host: ls16 Process: scanmgr File: cal_db_file_io.c Line: 1983 Function: CAL Processing : SBC Processing A corrupt file has been found in the cal database. The corrupt file has been removed from the cal database and saved for later analysis. Corrupt File: /usr/g/cal_db/kv120/large_sfov/16x0625/large_

Applies to

Models
HiSpeed
Product
HiSpeed QX/i - Octane Always MDAS4 101I.2_HSQXIM5 101.4_HSQXIM4 HiSpeed QX/i - Octane Method of visual identification Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config List of Supported Console Types Octane with Pegasus Recon hardware. List of softwares the product can run 101I.2_HSQXIM5 101.4_HSQXIM4 - obsolete FAQ's Table weight limit - Up to 400 lb. (180 kg) with ± .25 mm positional accuracy. 450Ib (205 kg) max weight Tube type - D3186T Current production details - See Technical Reference Manual found on the Common Document Library Tips and workarounds, where to find it - Common Document Library(CDL) . Search for the latest FMI software release. In the furnished materials will be the list of various manuals with part numbers for the various languages. Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Software
101I.2_HSQXIM5 See LD for ClassM & C 101I.2_HSQXIM5 used on HiSpeed (YMS) only Class M software - 2395173 or 2401759 (6 pack) Class C software - 2395172 or 2401759 (6 pack) Patch G.6 Mandatory FMI# 25363 (P/N 5136941)
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.