Pular para o conteúdo principal
GE Healthcare · CTLightSpeed

Lightspeed 1.X - Octane

Symptom

What is the Tube Mounting Hardware part number used on LightSpeed Systems?

Applies to

Models
LightSpeed
Product
Lightspeed 1.X - Octane 10.5_2.8.2I_H1.3M4 10.4.1_2.8.2I_H1.3M4 - obsolete Lightspeed 1.X - Octane Method of visual identification Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config showprods|grep Apps note: if check_config does not work then the software is not up to date with all FMI's. Check FMI history and verify that all patches have been loaded since last software reload. Ref FMI 25269 List of Supported Console Types Octane with Pegasus Recon hardware. may have an 02 SBC - Run df -k to see if the sbc is partitioned. List of softwares the product can run 10.5_2.8.2I_H1.3M4 10.4.1_2.8.2I_H1.3M4 - obsolete FAQ's Table weight limit - Up to 400 lb. (180 kg) with ± .25 mm positional accuracy. 450Ib (205 kg) max weight Tube type - D3176T Current production details - See Technical Reference Manual found on the Common Document Library Tips and workarounds, where to find it - Common Document Library(CDL) . Search for the latest FMI software release. In the furnished materials will be the list of various manuals with part numbers for the various languages. Example: English versions 2211223-100 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Component
2391264-2 PERFORMIX TUBE MOUNTING KIT See the LD for FEMC Comments 2391264-2 PERFORMIX TUBE MOUNTING KIT Part #: 2391264-2 Part Type: GP CONSUMABLES Part Weight: 0.00 LBR Repairable: No Returnable: No Hazardous Material: N Description: PERFORMIX MOUNTING KIT FOR FRU: Yes Status: Orderable Comments: FLS - LIGHTSPEED H/W KIT 2391264-2 THIS IS POKE-YOKE MOUNTING KIT FOR CT LIGHTSPEED SYSTEMS. THIS KIT CONTAINS MOUNTING HARDWARE FOR LIGHTSPEED SYSTEM INSTALLATIONS ONLY! THIS IS A REPLACEMENT FOR KIT CURRENTLY CONTAINED WITH THE TUBE. KIT CURRENTLY CONTAINED WITH TUBE DOES CONTAIN ALL HARD WARE NEEDED FOR INSTALLATION WITH ADDITIONAL HARDWARE FOR OTHER POSSIBLE INSTALLATIONS. IF THIS KIT IS NOT CURRENTLY AVAILABLE PLEASE USE EXISTING KIT SHIPPED WITH TUBE AND BE SURE TO MEASURE FOR PROPER INSTALLATION. MS13452 031117
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required

Related GE Healthcare CT issues