Service Note 43558_1 Nov/04 VGH New FOX-POP Board Upgrade Kit UGP001524
Symptom
Service Note 43558_1 Nov/04 VGH New FOX-POP Board Upgrade Kit UGP001524 Note 1: There are only 3 jumpers actually in place OJ1, OJ5 and OJ3 are in place. OJ2 and OJ4 are open. Service Note 43558 _1 Nov/04 VGH New FOX-POP Board UGP001524 Due to obsolescence of some components on the FOX and POP boards, they have been redesigned and combined into one board - the FOX POP board. Note 1: For VG and Infinia, There are only 3 jumpers actually in place OJ1, OJ5 and OJ3 are in place. OJ2 and OJ4 are open For VG with VTransact, Remove ALL jumpers.
Applies to
- Models
- Infinia
- Product
- VGH VG and VG Hawkey and Varicam
- Software
- VGH 6.0 VGH Acq 6.0 VG Acq 6.0 Part #: UGP001355 VG/DVG VER.6 KIT FOR SPARE PART (also see additional requirements below) Includes Software LSW000398 VG DVH HAWKEYE VER. 6 SW PACKAGE: Engineering Bill of Materials Name Description LSW000382 VG VH HAWKEYE Ver. 6 SW CD LSW000312 RCU for Dell 1400SC LSW000332 DISKETTE 1 SYSTEM LSW000403 Ver 6.0 Supplement 12 patch ver 6.0 build 7.5 (SN43633) LSW000426 VG Ver. 6 Motion and Worklist Patch.(SN43524) Also Includes: Software LSW000333 SOFTWARE PACKAGE FOR OLD COMPUTER VG: Engineering Bill of Materials Name Description LSW000011 DISKETTE 1 SYSTEM LSW000203 CKERMIT for GX200 LSW000022 SOFTWARE DELL ECU DISKETTE LSW000101 RCU for DELL 1300 ESW000637 HPC-HP 3COM LSW000404 DISKETTE 1 SYSTEM For HP NetServer Dell 2200 In addition VG requirements : UGP001583 VG Ver. 6.0 MUGA Patch LSW000490, FMI 40788 5195796 VG CoDe 2 Cold Spot, FMI 40805, CODE system only. 5169077 VG Software ver.6.0 Motion II ver. 2.0 patch 6.0P7 Service Note 43633 Optional: 5169169 Service Pack # 5169169 Q3 ver 2.0, SN43632
- Component
- *Gantry Gantry Gantry
- Area
- Nuclear Medicine
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare Nuclear Medicine issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare Nuclear Medicine issues
- Service Note 43783_1 Feb/08 Infinia/Ventri/Xeleris 1.1 & 2
- After software upgrade FMI40786, the Infinia application does not automatically start on boot up
- I need the product data sheet on catalog E4500AK x-ray in use warning light interface control panel for Infinia
- Infinia Does not recognize collimator is mounted to detector, not reading collimator ID correctly.
- Where do I obtain the Non-Linear Correction tables for a VG/Infinia Hawkeye system if can't find the CD that came with the DAS assembly?
- Hawkeye CT scan Ring (Circular) artifacts in X-ray images appearing in the same radius in all of the images.