GE Healthcare · CTLightSpeedVCT2601183113905452639048416245180
LightSpeed 5.X (80/100kW)
Symptom
Scanner Hardware Stopped Scan. Scanner Hardware Stopped Scan
Error message
Error: 260118311 Received command ignored. No action defined for current state. see long description for full error description Error: 260118311 Received command ignored. No action defined for current state. Thu Oct 13 13:59:13 2005 Error: 260118311 Host: orp Process: orp_subsys File: gen_exec.c Line: 936 Thu Oct 13 13:59:13 2005 Host : On-Board Rotating Processor Ermes # : 260118311 Exception Class : Abort Severity : Primary File : gen_exec.c Line# : 936 Function : No System Function Reported Scan Type : Helical Scan: 2163/4/1 Received command ignored. No action defined for current state. cmd: 30 (0x1e), state: 3 @Exp Cmd:: Tcks:39054526 Exp JEDI Resp:32 Rotor State:5 Last Acq Cmd:7 @Send Prep:: Line:4225 Tcks:39048416 JEDI State:2 Exp JEDI Resp:32 Rotor State:5 Last Acq Cmd Error: 245180 System aborted Xray-on Static scanning. Wed May 12 13:54:02 2004 Error: 245180 Host: ctpro100 Process: scanmgr File: scan_complete.cxx Line: 313 Function: System Control : Scan Control Scan Type: Xray-on Static Scan: 0/0/0 Scan Seq Id: 1000 System aborted Xray-on Static scanning. Views expected 992 Views collected 0 an updated version of this error Wed Feb 9 14:53:22 2011 Error: 245180 Host: ct0
Applies to
- Models
- LightSpeed, VCT
- Product
- LightSpeed 5.X (80/100kW) LightSpeed 5.X (80/100kW) ~ Use with both MDAS and GDAS ~ GRE Console HP_H_G16 HP_H_M16 HP_O_M16 LightSpeed 5.X (100kW) GDAS16 with GRE Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Component
- 5120819-2 RoHS Compliant Slipring Brushblock Assembly used on 5.X-7.X gantry. replaces 2349598 5120819 See long description for details 5120819-2 RoHS Compliant Slipring Brushblock Assembly Old FRU Compatible Yes Comments Per ECR 2087298, 212008898, 8/5/09. Additional FRU Needed No Old FRU Scrapped No Old FRU Upgradable No Use on Hands Yes Use Demand History Yes Ultimate Prime 5120819-2 New FRU Backward Compatible Yes Old FRU Usable Yes Change Type Indirect ECO Number ECR2087298 Part #: 5120819 Part Type: GP CONSUMABLES Part Weight: 0.00 LBR Repairable: No Returnable: No Hazardous Material: N Description: VCT Slipring Brushblock. Same as Hpower, but has additional voltage creepage distance for 208VAC. FRU: Yes Status: Orderable Comments: Added per ECR 2011062 new VCT Brushblock (5120819) on sliprings 2320265 and 2364819. Also added by VCT NPI RSPL UPDATE, ms13452 050916.
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required