MOD and CDROM not seen by system after installing new OC disk drive

Symptom

MOD and CDROM not seen by system after installing new OC disk drive

Error message

scsistat or HINV show same device listed multiple times See LD for complete error scsistat or HINV show same device listed multiple times. lct1 1# scsistat Device 1 1 Disk SEAGATE ST39216N FW Rev: 0010 <- OC Disk is listed as Device 1 2 Disk SEAGATE ST39216N FW Rev: 0010 device 1 through 7 ! ** Device 1 3 Disk SEAGATE ST39216N FW Rev: 0010 Device 1 4 Disk SEAGATE ST39216N FW Rev: 0010 Device 1 5 Disk SEAGATE ST39216N FW Rev: 0010 Device 1 6 Disk SEAGATE ST39216N FW Rev: 0010 Device 1 7 Disk SEAGATE ST39216N FW Rev: 0010 lct1 3# hinv Iris Audio Processor: version A2 revision 1.1.0 1 200 MHZ IP22 Processor FPU: MIPS R4000 Floating Point Coprocessor Revision: 0.0 CPU: MIPS R4400 Processor Chip Revision: 6.0 On-board serial ports: 2 On-board bi-directional parallel port Data cache size: 16 Kbytes Instruction cache size: 16 Kbytes Secondary unified instruction/data cache size: 2 Mbytes on Processor 0 Main memory size: 384 Mbytes EISA bus: adapter 0 Integral Ethernet: et0, IO0 Integral Ethernet: ec0, version 1 Integral SCSI controller 1: Version WD33C93B, revision D Disk drive: unit 7 on SCSI controller 1 Disk drive: unit 6 on SCSI controller 1 Disk drive: unit 5 on SCSI controller 1 Dis

Applies to

Models
HiSpeed
Product
HiSpeed CT/i 4.X HiSpeed CT/i 4.x with Zeus HSA Gantry and SGI Indigo Console HiSpeed CT/i with:HSA GANTRY CT/I (RHAPSODE) CONSOLE (Indigo Computer) Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Software
4.4.19.1 for HiSpeed CT/i with with CT/I (RHAPSODE) CONSOLE (Indigo) - showprods returns Rhapsode Product 4.4.19.1 4.4.19.1 for HiSpeed CT/i with with CT/I (RHAPSODE) CONSOLE (Indigo) - showprods returns Rhapsode Product 4.4.19.1 Intro. Date 10/18/00 Mandatory FMI 25268 Rhapsode Product 4.4.19.1 software for HiSpeed CT/i with SGI Indigo computer Intro. Date 10/18/00 Mandatory FMI 25268 Application Software Set Set Part No. . 2283723-3 Apps. CD Part No 2282440-3 Apps. Ver. 4.4.19M4 Apps. CD Label HiSpeed CT/I App SW showprods/Service Desktop Rhapsode Product 4.4.19.1 Class C CD Part No. Ver. CD Label 2282441-2 4.419M4 HiSpeed CT/I Class C Software Class M CD Part No. Ver. CD Label 2282442-2 4.419M4 HiSpeed CT/I Class M Software Patch Info: P/N 2318818, 4.5 Patch Rhapsode Product 4.4.19.1 Rhapsode patch 4.5.3 ver 1 11/21/2001 Optional FMI 25287A Also available via AutoSC ,_,Number:,2283723-3_______, ,BOM,Rev:,___,PI Rev:,___,CR Nb/Typ:,_______,___, ,CTZ,US, ,JAROSCH,ANN,K , ,Rev:,000,PI Rev:,000,CR Nb/Typ:, , , ,Description/Name:,E,HISPEED CT/I OPER SFWR VER 4.4.19 M4, ,Date:,2000-11-13, ,AIL:, , ,R,S,S,F, ,0001,/,0002, ,Mark, ,Number, ,Quantity,,U/M,U,T,P,C,Description/Name, ,__,1 ,2282439-2 , 1.000,PC ,S,N,N,N,IRIX 6.2M4 OS FOR 4.4 SOF, ,__,2 ,2282440-3 , 1.000,PC ,S,N,1,1,HISPEED CT/I APP SFWR VER, , , , , , , , , , , ,
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.