GE Healthcare · CTLightSpeed2300150355120052300150132300150222300150241127205412
Restore calibration files from valid systaem state
Symptom
Fastcals failed to complete. Fastcals failed to complete
Error message
Error: 230015035 Cal_db failure See LD for complete error Tue Oct 18 07:20:43 2005 Error: 230015035 Host: ctls3 Process: scanmgr File: cal_db_file_io.c Line: 762 Cal_db failure, error number = 12, reason: Not enough space Tue Sep 20 08:36:512005 Error: 230015035 Host: ls16 Process: scanmgr File: cal_db_file_io.c Line: 231 Cal_db failure, error number = 98, reason: Address already in use Error: 230015013 Failure opening a file for reading in the Cal Database. See LD for complete error Tue Sep 20 2005 08:36:512005 Error:230015013 Host: ls16 Process:scanmgr File: cal_db_file_io.c Line: 226 Function: CAL Processing : SBC Processing Failure opening a file for reading in the Cal Database. File:usr/g/cal_db/kv120/large_sfov/16x0625/large_spot/dasgain5/cal.1.sin Error: 230015022 Failure loading matrix decon kernel fields in cal module header. See Long Description for complete error Tue Oct 18 07:20:43 2005 Error: 230015022 Host: ctls3 Process: scanmgr File: cal_db_funcs.c Line: 264 Function: CAL Processing : SBC Processing Failure loading matrix decon kernel fields in cal module header. File: /usr/g/cal_db/misc/decon/4x125/cal.large_sfov.1.md Error: 230015024 A corrupt file has been fou
Applies to
- Models
- LightSpeed
- Product
- LightSpeed 3.X (Ultra, Plus, QX/i) - Octane Always 4 or 8 slice MDAS 308i.2_H3.1M5 LightSpeed 3.X - Octane Method of visual identification Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config List of Supported Console Types Octane with Pegasus Recon hardware. List of softwares the product can run 308I.2_H3.1M5 305.4_H3.1M4 - obsolete 303.1_H3M4 - obsolete FAQ's Table weight limit - Up to 400 lb. (180 kg) with ± .25 mm positional accuracy. 450Ib (205 kg) max weight Tube type - D3186T Current production details - See Technical Reference Manual found on the Common Document Library Tips and workarounds, where to find it - Common Document Library(CDL) . Search for the latest FMI software release. In the furnished materials will be the list of various manuals with part numbers for the various languages. Example: English versions 2211223-100 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required