GE Healthcare · CTLightSpeed200900025
LightSpeed 4.X - GRE
Symptom
Connect Pro Modality Work List will not update. Connect Pro Modality Work List will not update
Error message
Error: 200900025 Generic Patient Worklist Error , See Long Description for full errors See Long Description for errors The error can be in different contexts per the below Thu Jan 4 10:12:21 2007 Error: 200900025 pct01 WLServer WLapiSystem.c 190 Function: Data Management : OC Processing Patient Worklist Manager error. Source File: WLServer.c, Line: 1609, Status: 28 Fatal Unknown DCM ERROR Mon Sep 19 08:28:09 2005 Error: 200900025 ct01 piRxMgmt WLapiSystem.c 190 Function: Data Management : OC Processing Patient Worklist Manager error Source File: WLapiWorklistFile.c, Line: 6038, Status: 3 WLgetTime(): Could not read from /usr/g/db/patientInfo/Update.db. PS000007990.db for reading. Error: 200900025 Host: ls08 Process: WLServer File: WLapiSystem.c Line: 190 Function: Data Management : OC Processing Patient Worklist Manager error. Source File: WLS_mfm.c, Line: 1465, Status: 23 Parse Failed : Patient Worklist Manager HIS(40)(3) :-104 Error: 200900025 Process: WLServer File: WLapiSystem.c Line: 190 Function: Data Management : OC Processing Patient Worklist Manager error. Source File: WLServer.c, Line: 293, Status: 19 DICOM Association Inactivity Time-out Tue Sep 26 09:51:49 2006 Error: 2
Applies to
- Models
- LightSpeed
- Product
- LightSpeed 4.X - GRE See Long Description for detailed information - H2_P_M16 Product Name: LightSpeed 4.X with GRE Product Photographs GE HEALTHCARE Method of remote or software identification - See attachment below for a complete list of software commands and typical results 1. check_config 2 . swhwinfo “swhwinfo” will have the following switches: · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) -h or –help = Outputs complete details about all the available switches associated with swhwinfo swhwinfo –c –m –o -da List of Supported Console types: GOC3 (GRE) GOC4 (GRE) List of software the product can run: 07MW11.10 SP2.0, SP3.0, SP3.1 FAQ's Table weight limit - 180 kg (400 lbs) normal operation - 205 kg (450 lbs) maximum allowed with decreased accuracy Tube type - D3186T D3186T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Software
- 405L.8_H4.2M4 for LightSpeed 4.X (LightSpeed 16) with Console GOC2 (w/Linux PC) (2315653) or Xtream (GRE) Console 405L.8_H4.2M4 for LightSpeed 4.X (LightSpeed 16) with Console GOC2 (w/Linux PC) (2315653) or Xtream (GRE) Console 405L.8_H4.2M4 for LightSpeed 4.X (LightSpeed 16) with Console GOC2 (w/Linux PC) (2315653) or Xtream (GRE) ConsoleClass C Application Software Set CD Part No. Ver. CD Label CD Part No. Ver. CD Label Set Part No. Apps. CD Part No Apps. CD Label showprods/ Service Desktop Intro. Date Comment 2394897) 1104L.3_ H4.2CLASSC LightSpeed/ HiSpeed QXi Class C Software M4 5111370 5111371 LightSpeed 4.X Applications Software 405L.8_H4.2M4 FW11-04 FMI 25338
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.