GE Healthcare · CTLightSpeed1831825000144858

Lightspeed 1.X - Octane

Symptom

"Scan hardware Stopped Scan" with PDU errors "Scan hardware Stopped Scan" with PDU errorss

Error message

Error: 183182 I/O board pilot relays are closed. PDU pilot relay not energized. HVDC Rail Voltage is xxxx See Long Description for more details. Error: 183182 I/O Bd. pilot relays are closed. PDU pilot relay not energized. HVDC is xxxx. ** Note the HVDC Rail Voltage. It is important in troubleshooting Tue Sep 21 06:13:59 2004 Error: 183182 Host: OBC Process: Generator Function: SYSTEM POWER CONTROL: HVDC Control Scan: 50001/1/1 Type: Axial Exception Level: Pri/Most Severe I/O board pilot relays are closed. PDU pilot relay not energized BCSTAT = 0 HVDC Rail voltage = 0V Sun Dec 12 18:11:57 2004 Error: 183182 Host: OBC Process: Generator File: gen_rotor.c 1.39 Line: 488 Function: SYSTEM POWER CONTROL : HVDC Control Scan: 44858/1/1 Type: Scout Exception Level: Pri/Most Severe Time: 18:11:57:355 Log Series: 807 I/O board pilot relays are closed. PDU pilot relay not energized. BCSTAT = 0 HVDC Rail voltage = 210V If the rail voltage is approximately 200 Volts, you are missing one phase and most likely, a blown fuse is the culprit. HVDC Rail voltage = somewhere near 100 V This in-between voltage probably indicates bad C1 C2 capacitors or 3 phase Bridge Rect. or other PDU Control Bd. probl

Applies to

Models
LightSpeed
Product
Lightspeed 1.X - Octane 10.5_2.8.2I_H1.3M4 10.4.1_2.8.2I_H1.3M4 - obsolete Lightspeed 1.X - Octane Method of visual identification Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config showprods|grep Apps note: if check_config does not work then the software is not up to date with all FMI's. Check FMI history and verify that all patches have been loaded since last software reload. Ref FMI 25269 List of Supported Console Types Octane with Pegasus Recon hardware. may have an 02 SBC - Run df -k to see if the sbc is partitioned. List of softwares the product can run 10.5_2.8.2I_H1.3M4 10.4.1_2.8.2I_H1.3M4 - obsolete FAQ's Table weight limit - Up to 400 lb. (180 kg) with ± .25 mm positional accuracy. 450Ib (205 kg) max weight Tube type - D3176T Current production details - See Technical Reference Manual found on the Common Document Library Tips and workarounds, where to find it - Common Document Library(CDL) . Search for the latest FMI software release. In the furnished materials will be the list of various manuals with part numbers for the various languages. Example: English versions 2211223-100 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Component
2302508 Slip-ring Power Brush block See LD for details Part #: 2302508 Part Type: GP CONSUMABLE - RETURNABLE Part Weight: 0.50 LBR Repairable: No Returnable: Yes Hazardous Material: N Description: POWER BRUSHBLOCK - REPLACEMENT FRU: Yes Status: Orderable Comments: FLS - POWER BRUSH BLOCK. ADDED PER PCN 220302. REPLACES P/N 2177224. USE UP EXISTING STOCKOF P/N 2177224 FIRST! ADDED BY MS20544. DO NOT MIX ETC AND SCHLIEFRINGBRUSHES ON THE SAME RING, PER CT SERVICE. MS20544 ON 6/21/02 DO NOT DISCOUNT - PER SHAKUN PER ANJANA VENDOR: SCHLEIFRING MEDICAL SYSTEMS ******************************ELGIN IL READ FE ASSIST NOTES TO FE FOR EVERY ORDER SEE FE NOTE ****************************** PF8 ONE MORE TIME FOR FE ASSIST COMMENTS!!! FLS - FE ASSIST: MS06588 JULY 2002 2302508 = SCHLEIFRING POWER BRUSH BLOCK REPLACES ETC MFG'DBRUSH BLOCKS USED ON HSA, CT/IAND LIGHTSPEED QXI, GREEN DRUMSTYLE SLIP RING. DO NOT MIX ETC AND SCHLEIFRINGSIGNAL BRUSHES ON THE SAME TRACK PER CT SERVICE ENGINEERING MS20544 SIGNAL BRUSH BLOCKS MUST BE MFG'D BY THE SAME VENDOR THAT IS, DO NOT MIX AND MATCH ETC AND SCHLIEFRING SIGNAL BRUSH BLOCKS. ANY MATCHED PAIR OF SIGNAL BRUSH BLOCKS MAY BE INSTALLED WITH EITHER POWER BRUSH BLOCK.CTSE, MS03185. CAUTION! MANUALLY ROTATE AND CHECK FOR ANY INTERFERENCE AFTER BRUSH REPLACEMENT.
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.