GE Healthcare · CTLightSpeed200108010200108011230015037
LightSpeed 3.X (Ultra, Plus, QXi) - GOC2
Symptom
Fastcal scan aborts. Problem finding a calibration vector or calibration file.
Error message
Error: 200108010 This system has not been fully calibrated for XXX kV. You will not be able to scan at XXX kV until the system has been calibrated for this kV. See Long Description for complete error Mon Jun 20 07:06:46 2005 Error: 200108010 Host: ctxm Process: scanRx File: SIRx.cxx Line: 2380 Function: Data Acquisition : OC Processing This system has not been fully calibrated for 120 kV. You will not be able to scan at 120 kV until the system has been calibrated for this kV. Error: 200108011 The following calibration vector is not valid: See Long Description for complete error Mon Jun 20 07:06:46 2005 Error: 200108011 Host: ctxm Process: scanRx File: CalStatusInfo.cxx Line: 554 Function: Data Acquisition : OC Processing The following calibration vector is not valid: kV:120 sfov:SFOV_LARGE collimation:0 spotsize:LARGE_SPOT. Error:230015037 /usr/g/cal_db/kv120/large_sfov/1x125/large_spot/dasgain8/cal.1.acal has size: 0 See Long Description for complete error Mon Jun 20 07:06:45 2005 Error: 230015037 Host: ctxm Process: accs File: cal_db_utils.c Line: 1078 /usr/g/cal_db/kv120/large_sfov/1x125/large_spot/dasgain8/cal.1.acal has size: 0
Applies to
- Models
- LightSpeed
- Product
- LightSpeed 3.X (Ultra, Plus, QX/i) - GOC2 This is HP CPU host running LINUX with Pegasus IG. 308L.8_H3.3M4 ~ 4 or 8 slice MDAS. ~ Could be an Ultra, Plus or QXi system. Must run swokinstall -p to verify. ~ See Long description for details . LightSpeed 3.X MDAS4 Gantry and GOC2 Gantry - 2281177-2, DAS - 2272768, Console – 2341104-2, Table - 2276776, PDU - 2269902 Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Software
- 308L.8_H3.3M4 for LightSpeed 3.X (Ultra, Plus, QX/I with Console GOC2 (w/Linux PC) Assembly (2315653) or Xtream (GRE) Console - showprods returns 308L.8_H3.3M4 for LightSpeed 3.X (Ultra, Plus, QX/I with Console GOC2 (w/Linux PC) Assembly (2315653) or Xtream (GRE) Console - showprods returns 308L.8_H3.3M4 for LightSpeed 3.X (Ultra, Plus, QX/I with Console GOC2 (w/Linux PC) Assembly (2315653) or Xtream (GRE) Console
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required