GE Healthcare · CTLightSpeedHiSpeed200281001
Unable to view the network send queue or film composer queue
Symptom
Unable to view the network send queue or film composer queue
Error message
Error: 200281001 Status update: Film composer process terminated with status 0 Wed Nov 24 11:21:02 2004 Error: 200281001 Host: plsu Process: visScript File: VavFilmComposer.cxx Line: 180 Status update: Film composer process terminated with status 0 200281001 Status update: Film composer process terminated with status 0 Wed Nov 24 11:21:02 2004 Error: 200281001 Host: plsu Process: visScript File: VavFilmComposer.cxx Line: 180 Status update: Film composer process terminated with status 0 Error: 9001 Unable to set connection - server NETserver host plsu See LD for complete error Wed Nov 24 11:21:07 2004 Error: 9001 Host: plsu Process: film_composer File: application.c Line: 274 Unable to set connection - server NETserver host plsu. Tue May 17 20:23:24 2005 Error: 9001 Host: rhapsmct1 Process: netserver File: application.c Line: 215 Unable to set connection - server ARSserver host rhapsmct1.
Applies to
- Models
- LightSpeed, HiSpeed
- Product
- LightSpeed RT4 WB O G4 G HPT WB O M4 G HPT LightSpeed RT4 with GRE and MDAS4 or GDAS4 gantry At GE Medical Systems, we’re pioneering exciting CT technology for Radiation Therapy planning. Introducing the newest addition to our LightSpeed® series – LightSpeed RT, the first multi-slice, wide-bore CT scanner with the largest field of view in the industry. With a generous 80 cm gantry opening, the LightSpeed RT bore is 10 cm larger than conventional scanners. This provides complete flexibility for patient positioning freedom – even for the most demanding oncology needs. And the 65 cm variable field of view delivers 15 additional centimeters of visual coverage, allowing clinicians to see a patient’s entire anatomy for precise radiation therapy planning. Position and precision Thin, multi-slice imaging is the extra bonus – enabling respiratory gating, providing precise target delineation and delivering higher resolution digitally reconstructed radiographs (DRRs) than ever before. All adding up to the ability for you to deliver what really matters most – better cancer care for your patients. Plus, the LightSpeed RT scanner is available with the Exact™ couch insert, enabling you to consistently replicate patient immobilization for treatment. With LightSpeed RT, the future of your Radiation Oncology department is wide open. Links to the Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Software
- 04MW44.9 for all LightSpeed systems with GRE/Xtream consoles (QXi, PLUS, ULTRA, LS16, PRO 16, RT)(1.X, 2.X, 3.X, 4.X, 5.X) Open Long Description for details. 04MW44.9 for all LightSpeed systems with GRE/Xtream consoles (QXi, PLUS, ULTRA, LS16, PRO 16, RT)(1.X, 2.X, 3.X, 4.X, 5.X) 04MW44.9A signifies Patch A has been loaded on a HP60 system. Class C Class M Application Software Set CD Part No. Ver. CD Label CD Part No. Ver. CD Label Set Part No. Apps. CD Part No Apps. CD Label showprods/ Service Desktop Intro. Date Comment 5135965 Supports Software 04MW44.9 on GRE/Xtream Class C For use on GRE/Xtream consoles on LightSpeed 5X Series H-Power 60/80/100 and MDAS-RT 5135966 Supports Software 04MW44.9 on GRE/Xtream Class M For use on GRE/Xtream consoles on LightSpeed 5X Series H-Power 60/80/100 and 5X MDAS-RT 5135967 5135962 Applications Disk 1 5135963 Applications Disk 2 5135964 DARC Applications Disk 2399296 Operating System, Ver 1.7.10 Disk 2399297 Serial Over LAN Disk 04MW44.9 May 2005 FMI 25351 For HP100, HP80, and RT Only The GRE Common Applications software supports multiple hardware configurations via a single software set. The new software version string has the following format: <software_label>.<G>_<T>_<D>_<R> The "software label" format is: YYLWxx.ZZ Where: YY = Year. For example 04. L = Location. M - Milwaukee, H - Hino, B - Beijing. Wxx = Fiscal Week. For example, W15. ZZ = Revision number for each build/reroll. Refer to Table B for an explanation of the <G>_<T>_<D>_<R> format. Table B Common Applications Sotware Naming Convention G = GANTRY TYPE T = TUBE TYPE D = DAS TYPE R = RECON HW TYPE H1 = LightSpeed 1.X P = Performix S4 = SDAS4 P = Pegasus H2 = LightSpeed 2.X, 3.X, 4.X O = OEM M4 = MDAS4 G = GRE HP = LightSpeed 5.X H = Hercules M8 = MDAS8 WB = LightSpeed 5.x RT M16 = MDAS16 QX = HighSpeed QXi G16 = GDAS16 The variables G, T, D, and R are generated dynamically based on the type of hardware configuration this software is installed on. The information for the dynamic part of the string is obtained from the INFO files which are located in /usr/g/config directory. An example string based on the above format is as follows: 04MW13.7.H2_P_M4_G The break down is as follows: This is 2004 software release at Milwaukee in Fiscal Week 13 with a revision number "7". The hardware configuration is "H2" gantry with "Performix" tube, "MDAS4", and "GRE" recon hardware. CDL Links: DIRECTION 2378261-100 GRE SOFTWARE INSTALLATION PROCEDURES Direction 2407441-100 Common Platform Q4 2004 Release Application Tips and Work-Arounds
- Area
- CT