GE Healthcare · CTLightSpeedVCT2601346282621120260134634284000225000
LightSpeed 7.x (VCT, VCT Select, Pro32)
Symptom
Table will not move. Table will not move
Error message
Error: 260134628 GTCB Cradle incorrect motion with move command See LD for complete error Wed May 11 12:27:54 2005 Error: 260134628 Host: tgp Process: tgp_subsys File: gtcb_cmcmon_actions_const.cxx Line: 305 Wed May 11 12:27:54 2005 Host : Table Sub-System Ermes # : 260134628 Exception Class : Secondary Severity : Pri/Soft File : gtcb_cmcmon_actions_const.cxx Line# : 305 Function : No System Function Reported Scan Type : None/Unknown Scan: 1301/3/0 GTCB Cradle incorrect motion with move command current pos = 2621120 target speed = 5000 um/s expected move = 2500 um actual move = 310 um (linear), 163 um (abs) Error: 260134634 Cradle task received invalid corrected speed from cradle monitor See LD for complete error May 12 06:36:02 2005 Error: 260134634 Host: tgp Process: tgp_subsys File: gtcb_cmc_profile.cxx Line: 537 Thu May 12 06:36:02 2005 Host : Table Sub-System Ermes # : 260134634 Exception Class : Secondary Severity : Pri/Soft File : gtcb_cmc_profile.cxx Line# : 537 Function : No System Function Reported Scan Type : None/Unknown Scan: 0/0/0 Cradle task received invalid corrected speed from cradle monitor task. received 284000 um/s expected 1 to 225000 um/s
Applies to
- Models
- LightSpeed, VCT
- Product
- LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required