LightSpeed 7.x (VCT, VCT Select, Pro32)
Symptom
Image recon is failing intermittently - document in RFS - critical issue See long description for details. Image recon is failing intermittently.
Error message
Error: 290009001The scanfile does not have enough views to make requested images. See LD Error: 290009001The scanfile does not have enough views to make requested. Tue Dec 6 11:07:48 2005 Error: 290009001 Host: darc Process: recon_control File: ImageSetRequest.cxx Line: 2684 The scanfile does not have enough views to make requested images. exam/series/scan = 60/2/1 expected number of images = 12 created number of images = 0 max number of images = 12 scan completed = 1 Error: 290009009 Image failed due to: IG error: NOT_ENOUGH_VIEWS Fri Jan 18 06:03:34 2008 Error:290009009 Host: darc Process: recon_control File: ImageSetRequest.cxx Line: 6076 Function: Image Generation : SBC Processing Image failed due to: IG error: NOT_ENOUGH_VIEWS. Number of retry so far: 1. IG node: 1
Applies to
- Models
- LightSpeed, VCT
- Product
- LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
- Software
- 11HW12.5 LightSpeed VCT Quatra with Titan configuration supports Sherlock and Halo detectors for GOC6 & GOC6.5 consoles 11HW12.5 released in forward production 3rd quarter 2011. Also released via FMI 25427 classC 5423514 classM 5423515 Details : 11HW12.5 for VCT Quatra is being released to introduce the Dose Check feature and to fix software issues in 10MW06.5 software. For a list of features released by VCT Quatra please refer to SN10120810a (iSERV for VCT Quatra). Furthermore, this software package will bereleased as an FMI to all VCT systems with GOC6 or GOC6.5 consoles. Customers with older software versions will also receive fixes that were part of the Titan release (10MW06.5) and Vision release (09MW08.10 or 09MW08.11).
- Area
- CT