GE Healthcare · CTLightSpeedVCT26011201513070
LightSpeed 4.X - GRE
Symptom
Customer was not able to remote tilt gantry. In many cases , gantry will tilt from the Gantry Controls.
Error message
Error: 260112015 The Gantry Touch Sensor FAULT ( error text varies ) See long description for error examples Error text varies. Tue Sep 4 10:28:17 2007 Error: 260112015 Host: tgp Process: tgp_subsys File: uif_table_tilt_mgr_gt.c Line: 9075 Tue Sep 4 10:27:02 2007 Host : Table Gantry Processor Ermes # : 260112015 Exception Class : Secondary Severity : Pri/Soft File : uif_table_tilt_mgr_gt.c Line# : 9075 Function : PATIENT ANATOMY POSITIONING : Tilt Drive Scan Type : None/Unknown Scan: 6891/2/0 The Gantry Touch Sensor FAULT. Gantry Sensors: BACK Touch Sensor Error(s). Gantry Controls are running in FAULT MODE. Operator's Console Remote Tilt button is DISABLED. Use local gantry controls to tilt the gantry Sat Nov 17 00:07:55 2007 Error: 260112015 Host: tgp Process: tgp subsys File: uif table tilt mgr gt.c Line: 13070 Sat Nov 17 00:07:54 2007 Host : Table Gantry Processor Ermes # : 260112015 Exception Class : Secondary Severity : Pri/Soft File : uif table tilt mgr gt.c Line# : 13070 Function : PATIENT ANATOMY POSITIONING : Tilt Drive Scan Type : None/Unknown Scan: 0/0/0 The Gantry Touch Sensor FAULT. Gantry Sensors: FORWARD Touch Sensor Error(s). Gantry Controls are running in FAULT MO
Applies to
- Models
- LightSpeed, VCT
- Product
- LightSpeed 4.X - GRE See Long Description for detailed information - H2_P_M16 Product Name: LightSpeed 4.X with GRE Product Photographs GE HEALTHCARE Method of remote or software identification - See attachment below for a complete list of software commands and typical results 1. check_config 2 . swhwinfo “swhwinfo” will have the following switches: · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) -h or –help = Outputs complete details about all the available switches associated with swhwinfo swhwinfo –c –m –o -da List of Supported Console types: GOC3 (GRE) GOC4 (GRE) List of software the product can run: 07MW11.10 SP2.0, SP3.0, SP3.1 FAQ's Table weight limit - 180 kg (400 lbs) normal operation - 205 kg (450 lbs) maximum allowed with decreased accuracy Tube type - D3186T D3186T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required