GE Healthcare · Nuclear MedicineInfinia105011180110502
Unable to start Hawkeye CT Scan - Uncaught exception, Could not perform the operation
Symptom
Unable to start Hawkeye CT Scan - Uncaught exception, Could not perform the operation
Error message
ERROR_ACQ_ACTION_FAILED,10501,ERROR ERROR_ACQ_ACTION_FAILED,10501,ERROR [email protected]: 08:43:00 ERROR = Error in Activity ID:0 Stack trace:com.ge.med.fi.tacq.sequence.SequenceException: Failed to Setup (ERROR_ACQ_ACTION_FAILED,10501,ERROR) at com.ge.med.fi.tacq.te.TESequence.setup(TESequence.java:882) at com.ge.med.fi.tacq.gui.SequenceControlUI$15.doWork(SequenceControlUI.java:545) at com.ge.med.fi.tacq.gui.util.SwingWorker.construct(SwingWorker.java:79) at com.ge.med.fi.tacq.gui.util.SwingWorker$4.run(SwingWorker.java:195) at java.lang.Thread.run(Unknown Source) Caused by: com.ge.med.fi.tacq.sequence.SequenceException: CT scan is not allowed now. Reason: Air correction table for H-mode, 140 kV is out of date or missing. (CT_SCAN_IS_NOT_ALLOWED,11801,ERROR) at com.ge.med.fi.tacq.te.TESequence.verifyCTStatus(TESequence.java:2343) at com.ge.med.fi.tacq.te.TESequence.setup(TESequence.java:862) ... 4 more Source:not stated Description:com.ge.med.fi.tacq.sequence.SequenceException: Failed to Setup (ERROR_ACQ_ACTION_FAILED,10501,ERROR) ERROR_UN_CAUGHT_ERROR,10502 Uncaught exception ERROR_UN_CAUGHT_ERROR:.:Could not perform the operation:.:1. Try again 2. Restart the Application:.: U
Applies to
- Models
- Infinia
- Product
- Infinia HE4 Infinia II Hawkeye 4 & Infinia II GP (Infinia running Windows XP software)
- Component
- *Software Software Software
- Area
- Nuclear Medicine
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare Nuclear Medicine issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare Nuclear Medicine issues
- Service Note 43783_1 Feb/08 Infinia/Ventri/Xeleris 1.1 & 2
- After software upgrade FMI40786, the Infinia application does not automatically start on boot up
- I need the product data sheet on catalog E4500AK x-ray in use warning light interface control panel for Infinia
- Infinia Does not recognize collimator is mounted to detector, not reading collimator ID correctly.
- Where do I obtain the Non-Linear Correction tables for a VG/Infinia Hawkeye system if can't find the CD that came with the DAS assembly?
- Hawkeye CT scan Ring (Circular) artifacts in X-ray images appearing in the same radius in all of the images.