LightSpeed 7.x (VCT, VCT Select, Pro32)

Symptom

Images Recon is very slow, some images taking 20 minutes to complete

Error message

Error: 245276 WARNING- Scan setup took 14721 ms on getting Cal Module. This could potentially cause scan timing issue or scan abort. See Long Description: Thu Apr 13 22:25:56 2006 Error: 245276 Host: ahi1 Process: scanmgr File: scanmgr_lib.cxx Line: 1197 Function: System Control : Scan Control Scan Type: Cine Scan: 0/0/0 Scan Seq Id: 319000 WARNING- Scan setup took 14721 ms on getting Cal Module. This could potentially cause scan timing issue or scan abort.

Error: 245275 WARNING- Scan setup took 4479 ms overall See long description Thu Oct 29 07:34:53 2009 Error: 245275 Host: vct Process: scanmgr File: scanmgr_lib.cxx Line: 1283 Function: System Control : Scan Control Scan Type: Cine Scan: 0/0/0 Scan Seq Id: 1212000 WARNING- Scan setup took 4479 ms overall. This could potentially cause scan timing issue or scan abort.

Applies to

Models
LightSpeed, VCT
Product
LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
Software
11HW12.5 LightSpeed VCT Quatra with Titan configuration supports Sherlock and Halo detectors for GOC6 & GOC6.5 consoles 11HW12.5 released in forward production 3rd quarter 2011. Also released via FMI 25427 classC 5423514 classM 5423515 Details : 11HW12.5 for VCT Quatra is being released to introduce the Dose Check feature and to fix software issues in 10MW06.5 software. For a list of features released by VCT Quatra please refer to SN10120810a (iSERV for VCT Quatra). Furthermore, this software package will bereleased as an FMI to all VCT systems with GOC6 or GOC6.5 consoles. Customers with older software versions will also receive fixes that were part of the Titan release (10MW06.5) and Vision release (09MW08.10 or 09MW08.11).
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.