GE Healthcare · CTLightSpeedVCT

LightSpeed 7.x (VCT, VCT Select, Pro32)

Symptom

Exam Split fails with no errors in gesyslog but with on screen messages. See Long Description for Details. Exam split fails with no errors in gesyslog but with on screen messages. On screen messages: Unable to send PPS for Requested Procedure CT Unable to send GSPS for Requested Procedure Errors From /usr/g/ctuser/logfiles/ExamSplit0.0.log: | 2007-1-2 16:23:37 | 12 | ExamSplit | 23 | ERROR | Network Send failed | com.ge.hc.examsplit.ApplicationOperations$1.java:189 | Unable to send PPS for Requested Procedure CT Abdomen Pelvis With ContrasttoDICOM_TEST_RMT Th is is be because of problems with the network session Stack Trace :: com.ge.med.terra.tap.dm.DMException: Connection refused at com.ge.med.terra.tap.dm.network.networkSession.install(networkS ession.java:419) at com.ge.med.terra.tap.dm.DMSession.install(DMSession.java:406) at com.ge.hc.examsplit.ApplicationOperations$1.run(ApplicationOper ations.java:158) at java.lang.Thread.run(Unknown Source) | 2007-1-2 16:23:52 | 12 | ExamSplit | 24 | ERROR | Network Send failed | com.ge.hc.examsplit.ApplicationOperations$1.java:220 | Unable to send GSPS for Requested Procedure CT Abdomen Pelvis With Contrast to SYNAPSEDICOM T his could be because of problems with the network session Stack Trace :: com.ge.med.terra.tap.dm.DMException: com.ge.med.terra.tap.dm.DMException: abstract syntax not supported at com.ge.med.terra.tap.dm.network.networkSession.install(networkS ession.java:419) at com.ge.med.terra.tap.dm.DMSession.install(DMSession.java:406) at com.ge.hc.examsplit.ApplicationOperations$1.run(ApplicationOper ations.java:215) at java.lang.Thread.run(Unknown Source)

Applies to

Models
LightSpeed, VCT
Product
LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
Software
11HW12.5 LightSpeed VCT Quatra with Titan configuration supports Sherlock and Halo detectors for GOC6 & GOC6.5 consoles 11HW12.5 released in forward production 3rd quarter 2011. Also released via FMI 25427 classC 5423514 classM 5423515 Details : 11HW12.5 for VCT Quatra is being released to introduce the Dose Check feature and to fix software issues in 10MW06.5 software. For a list of features released by VCT Quatra please refer to SN10120810a (iSERV for VCT Quatra). Furthermore, this software package will bereleased as an FMI to all VCT systems with GOC6 or GOC6.5 consoles. Customers with older software versions will also receive fixes that were part of the Titan release (10MW06.5) and Vision release (09MW08.10 or 09MW08.11).
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.