GE Healthcare · CTLightSpeedVCT26010009050234
LightSpeed 7.x (VCT, VCT Select, Pro32)
Symptom
"Scan hardware Stopped Scan" with PDU errors "Scan hardware Stopped Scan" with PDU errorss
Error message
Error: 260100090 The Kss Contactor Status Signal changed state unexpectedly. Contactor Status: Open See long description for details Tue Mar 11 20:26:37 2008 Error: 260100090 Host: tgp Process: tgp subsys File: scIsrService.c Line: 153 Tue Mar 11 20:26:37 2008 Host : Table Gantry Processor Ermes # : 260100090 Exception Class : Abort Severity : Primary File : scIsrService.c Line# : 153 Function : SYSTEM MONITORING : HVDC Monitor Scan Type : Axial Scan: 50234/1/2 PDU KSS Contactor Status. The Kss Contactor Status Signal changed state unexpectedly. Contactor Status: Open
Applies to
- Models
- LightSpeed, VCT
- Product
- LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
- Component
- 2351491 14-25A CONTACTOR - NGPDU Kss contactor See long Description Part #: 2351491 Part Type: GP CONSUMABLES Part Weight: 1.32 LBR Repairable: No Returnable: No Hazardous Material: N Description: 14-25A CONTACTOR FRU: Yes Status: Orderable Comments: FLS - 14-25A CONTACTOR. ADDED PER NGPDU RSPL FROM ASIA. MS20544 ON 1/2/03.
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required