Power Monitor Faults Due To Missing Or Broken Cable.
Symptom
Scan Aborts with Error code 2257270 The Universal Power Monitor 1 (and/or 2) detected too much amplifier reflected power (Body Channel). See long description Scan aborts with error code 2257270 on both power monitors, see below. Error: 2257270 Host: E-OP-MR1 Process: NSP File: SCP:UPM Line: 492 Exception Class: Unknown Severity: Unknown Function: RF: RF Power Monitor PSD: T1flair Coil: HDCTL TOP Scan: 53019/1 The Universal Power Monitor 1 detected too much amplifier reflected power (Body Channel). Forward Power = 73. Reflected Power = 10.-> ------------------------------------------------------------------------ Wed Feb 11 12:36:08 2009 Error: 2257270 Host: E-OP-MR1 Process: NSP File: SCP:UPM Line: 492 Exception Class: Unknown Severity: Unknown Function: RF: RF Power Monitor PSD: Gradient Echo Coil: 8HRBRAIN Scan: 53051/1 The Universal Power Monitor 2 detected too much amplifier reflected power (Body Channel). Forward Power = 1542. Reflected Power = 192.->
Error message
2257270 The Universal Power Monitor 1 detected too much amplifier reflected power (Body Channel) See long description Error: 2257270 Host: cmr2 Process: NSP File: SCP:UPM Line: 492 Exception Class: Unknown Severity: Unknown Function: RF: RF Power Monitor PSD: FSE-XL Coil: 8HRBRAIN Scan: 442/7 The Universal Power Monitor 1 detected too much amplifier reflected power (Body Channel). Forward Power = 4929. Reflected Power = 620.->
Applies to
- Models
- Signa
- Product
- 3.0T Signa HDxT For 3.0T Signa HDxT systems with 15.0 software only. For 3.0T Signa HDxT systems with 15.0 software only.
- Software
- 15.0 For Product Signa HDxT and HDi only. -- NOT to be used with HDe. -- For Product Signa HDxT and HDi only. -- NOT to be used with HDe. --
- Component
- 2416958 CABLE 3.0T TORSO HDMR2 2416958 CABLE 3.0T TORSO HDMR2
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- CWA How to Change Date or Time on LX, Excite, HD, HDe, HDx, HDxT, HFO, Excite HFO, Ovation1-4, Profile1-5, Discovery MR450 MR750 and Optima 450w Systems.
- CWA No Power to the Table and Magnet Display, Table Will Not Move And No Lights On the Magnet.
- CWA How to Change Exam Number from Remote Tools.
- Known Software issue with 15M4B coding error.
- Unable to Send Images to the PACS Due to PACS is down.
- U41 of the Slave RF Ctrl Assy, part of the PSU in the SRFD2 RF Amplifier Failed.