GE Healthcare · CTLightSpeedVCT230000860230000067300000
LightSpeed 7.x (VCT, VCT Select, Pro32)
Symptom
Scanner Hardware Stopped Scan. Scanner Hardware Stopped Scan
Error message
Error: 230000860 Error from DIP driver See Long Description for full error Thu Dec 22 18:59:52 2005 Error: 230000860 Host: darc Process: dataacq File: /home/ctuser/vdip-driver/vdip_func.c Line: 139 Error from DIP driver: timeout waiting for optical sync; link1[NO SYNC] link2[OK] bsr=0x1026 (Note: [NO SYNC] or [OK] indicates link status) 230000067 RX1 Scan data buffer over-run See Long Description for details of error Wed Nov 5 17:10:02 2008 Error: 230000067 Host: darc Process: dataacq File: vdip.cxx Line: 813 Function: Data Acquisition : Scan Data Acquisition Scan Type: Axial Scan: 1672/200/2 Scan Seq Id: 300000 Unexpected event occurred during scan data transfer. Event bit: 14 Count: 1 Description: RX1 Scan data buffer over-run Scan aborted.
Applies to
- Models
- LightSpeed, VCT
- Product
- LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
- Component
- 5159833 VDARC - Volume Data Acq Recon Control Computer, 2nd Edition (Jarrell). See Long Description for Details.. Part #: 5159833 Part Type: GP CONSUMABLE - RETURNABLE Part Weight: 0.00 LBR Repairable: No Returnable: Yes Hazardous Material: N Description: VDARC - Volume Data Acq Recon Control Computer, 2nd Edition FRU: Yes Status: Orderable Parts Offered as: Current : 5159833 Harvested : Not Available Exchange : Not Available Comments: Per Jarrell RSPL, 7/17/06, ms11892. ** FE Assist ** Must order software release 06MW29.7, p/n 5193989 and perform a LFC to support this FRU if system is not currently running 06MW29.7 or better.(12/8/06 212001261
- Area
- CT
Full cause & step-by-step resolution