Symptom

After cycling power a grey box is coming up with Panic bus error. See Long Description Dumping with reboot after panic: PANIC: Bus Error appearing in the SYSLOG Problem is consistent ct01 8# egrep "data|error|fail|hard|panic|retry|restart|soft|XIO" /usr/adm/SYSLOG* | more /usr/adm/SYSLOG:Aug 27 00:00:06 6F:ct01 syslogd: restart /usr/adm/SYSLOG:Aug 27 07:04:33 6A:ct01 unix: dksc1d6: <6>Device not ready<6> : Media load/unload failure (asc=0x53, asq=0x0)<6> /usr/adm/SYSLOG:Aug 27 07:04:55 6A:ct01 unix: dksc1d6: <6>Device not ready<6> : Media load/unload failure (asc=0x53, asq=0x0)<6> /usr/adm/SYSLOG.0:Aug 26 00:00:06 6F:ct01 syslogd: restart /usr/adm/SYSLOG.0:Aug 26 01:01:06 6F:ct01 syslogd: restart /usr/adm/SYSLOG.0:Aug 26 05:28:11 6A:ct01 unix: dksc1d6: <6>Device not ready< 6>: Media load/unload failure (asc=0x53, asq=0x0)<6> /usr/adm/SYSLOG.0:Aug 26 05:28:32 6A:ct01 unix: dksc1d6: <6>Device not ready< 6>: Media load/unload failure (asc=0x53, asq=0x0)<6> /usr/adm/SYSLOG.0:Dec 31 19:00:45 6F:ct01 syslogd: restart /usr/adm/SYSLOG.0:Dec 31 19:00:45 6A:ct01 unix: dksc1d6: <6>Device not ready< 6>: Media load/unload failure (asc=0x53, asq=0x0)<6> /usr/adm/SYSLOG.0:Dec 31 19:01:08 6A:ct01 unix: dksc1d6: <6>Device not ready< 6>: Media load/unload failure (asc=0x53, asq=0x0)<6> /usr/adm/SYSLOG.1:Aug 25 00:00:06 6F:ct01 syslogd: restart /usr/adm/SYSLOG.1:Aug 25 06:38:02 6A:ct01 unix: dksc1d6: <6>Device not ready< 6>: Media load/unload failure (asc=0x53, asq=0x0)<6> /usr/adm/SYSLOG.1:Aug 25 06:38:13 2E:ct01 savecore: reboot after panic: PANIC : Bus Error

Applies to

Product
Lightspeed 1.X - Octane 10.5_2.8.2I_H1.3M4 10.4.1_2.8.2I_H1.3M4 - obsolete Lightspeed 1.X - Octane Method of visual identification Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config showprods|grep Apps note: if check_config does not work then the software is not up to date with all FMI's. Check FMI history and verify that all patches have been loaded since last software reload. Ref FMI 25269 List of Supported Console Types Octane with Pegasus Recon hardware. may have an 02 SBC - Run df -k to see if the sbc is partitioned. List of softwares the product can run 10.5_2.8.2I_H1.3M4 10.4.1_2.8.2I_H1.3M4 - obsolete FAQ's Table weight limit - Up to 400 lb. (180 kg) with ± .25 mm positional accuracy. 450Ib (205 kg) max weight Tube type - D3176T Current production details - See Technical Reference Manual found on the Common Document Library Tips and workarounds, where to find it - Common Document Library(CDL) . Search for the latest FMI software release. In the furnished materials will be the list of various manuals with part numbers for the various languages. Example: English versions 2211223-100 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Component
2169940-81 Octane Computer 73 GB Disk Drive - replaces 2169940-78 (18GB) See long description for aditional information 2169940-81 Octane 73 GB Disk Drive, replaces 18 GB Disk 2169940-78 Part #: 2169940-81 Part Type: GP CONSUMABLES Part Weight: 2.18 LBR Repairable: No Returnable: No Hazardous Material: N Description: CT OCTANE 2 73 GB DISK DRIVE FRU: Yes Status: Orderable
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required

Related GE Healthcare CT issues