GE Healthcare · CTLightSpeedVCT2300110792450611342000230019002
LightSpeed 7.x (VCT, VCT Select, Pro32)
Symptom
"Scan hardware Stopped Scan" with scan data errors. "Scan hardware Stopped Scan" with scan data errors
Error message
Error: 230011079 Error detected closing a scan file header on the scan data disks. See LD for complete error 230011079 Error detected closing a scan file header on the scan data disks Mon Nov 8 11:15:12 2004 230011079 6 hmaich_gels_ct4 scanmgr sdio_xfs_io_ops.c 1094 Function: Data Acquisition : SBC Processing Scan Type: Helical Scan: 6826/2/1 Scan Seq Id: 4000 Error detected closing a scan file header on the scan data disks. Scan: CT20/6826/2/1 Descriptor: 33 Unix system error : 98 --- Protocol wrong type for socket. Some views may be unavailable for reconstruction until the system is restarted. Error: 245061 Process: scanmgr SCNMGR_ACQUISITION_DONE event was not received See LD for complete error Wed Feb 28 17:50:15 2007 Error: 245061 Host: ct99 Process: scanmgr File: norm_and_gen_timeouts.cxx Line: 90 Function: System Control : Scan Control Scan Type: Helical Scan: 0/0/0 Scan Seq Id: 1342000 SCNMGR_ACQUISITION_DONE event was not received Error: 230019002 The scan disk I/O layer failed to consume a response from the scan disk server. See LD for complete error Tue Nov 2 03:19:30 2004 Error: 230019002 Host: sgredct1 Process:scanfilemgr File: sdio proxy.c Line:174 The scan disk I/O
Applies to
- Models
- LightSpeed, VCT
- Product
- LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
- Software
- 11MW4.1 LightSpeed VCT Quatra with Titan configuration supports Sherlock and Halo detectors for GOC6.5 consoles This software is now obsolete, this site should be upgraded to 11HW12.5 software released via FMI 25427 11MW4.1 LightSpeed VCT Quatra with Titan configuration supports Sherlock and Halo detectors for GOC6.5 consoles 11MW4.1 sofware is forward production software there are no plans to FMI it. The 11MW4.1 software Is basically quatra software “LightSpeed VCT Quatra 10MW44.X”. We have a new FMI going out that will cover all of the GOC6 series console that release is call Dose Check 11HW12.4 The only difference between 10MW44.X and 11MW4.1 is that 11MW4.1 is supports Sherlock and Halo detectors for GOC6.5 consoles. 11HW12.4 will be fmi’d to all GOC6 and GOC6.5 the software is called “Quatra Dose Check”
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required