GE Healthcare · CTDiscovery26010500450364260118418
Scanner Hardware Stopped Scan.
Symptom
Scanner Hardware Stopped Scan. Scanner Hardware Stopped Scan
Error message
Error: 260105004 (20-0270) Vbias too low. Focal spot width and position affected Please see the Long Description for full error Sat May 8 10:16:13 2010 Error: 260105004 Host: orp Process: orp subsys File: gen exec.cxx Line: 2792 Sat May 8 10:16:12 2010 Host : Jedi Ermes # : 260105004 Exception Class : Secondary Severity : Pri/Soft File : gen exec.cxx Line# : 2792 Function : No System Function Reported Scan Type : Axial Scan: 50364/1/1. (20-0270) Vbias too low. Focal spot width and position affected Error: 260118418 Length Bias Control Voltage were out of range See long description It was in unknown status. Sun Sep 6 17:16:40 2009 Error: 260118418 Host: orp Process: orp_subsys File: genJediSC.cxx Line: 1850 Sun Sep 6 17:16:38 2009 Host : On-Board Rotating Processor Ermes # : 260118418 Exception Class : Secondary Severity : Sec/Soft File : genJediSC.cxx Line# : 1850 Function : No System Function Reported Scan Type : Scout Scan: 6694/1/1 Length Bias Control Voltage were out of range. It was in unknown status. Where Technique: kV:120 mA:10 FS(1:S 2:L 4:XL):1 1 Point ExpTime(mS):2785 Rotor Speed (2:LOW 4:HIGH):2 GenOptions:0x8 and Freq: 1100(Hz)
Applies to
- Models
- Discovery
- Product
- Discovery CT750 HD V40_PS_HD64_G_GTL V40_PS_HD64_G_GTM Discovery HD CT750 Method of visual identification HD gantry: Gray top and Gray Side covers with HD Markings Console Type: GOC6 has black SCIM and tower face Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) -h or –help = Outputs complete details about all the available switches associated with swhwinfo swhwinfo –c –m –o -da List of softwares the product can run (Consult attached FCT Software Cross Reference): 08MW39.4 - M3 (see attachement for M3 available options) 09MW29.14 - M4 (HD Options = M3 plus Gemstone Spectral Imaging, Gemstone Spectral Review and volume Helical Shuttle ) Example: Of difference with options software [insite@ct01 ~]$ swokinstall -p Product Software Option Keys: Gemstone Spectral Imaging Permanent HelicalShuttle Permanent Xtream Recon Permanent FAQ's Table weight limit: 500 lbs Tube Type - D3702T Green D3701T Current production - M4 Refer to product data sheets or Technical reference Manual, English 5317222-1EN Revision : 2 or later Refer to Application Tips and Work-Arounds Direction 5311815-1EN Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required