LightSpeed/Discovery CT750 HD

Symptom

Fast Cals Aborted See Long Description Scanner Hardware stopped Scan during Fast Cals

Error message

Error: 245194 reading the tube state file (elapsed time = -9999.000000). Resetting the tube state to HOT to reduce risk to the tube. ERROR: 245194 reading the tube state file (elapsed time = -9999.000000). Resetting the tube state to HOT to reduce risk to the tube. Fri Apr 22 07:45:10 2005 Error: 245194 Host: eastct2 Process: scanmgr File: tube_cooling.cxx Line: 111 Function: No system function reported Scan Type: Not scanning Scan: 0/0/0 Scan Seq Id: 0 Error reading the tube state file (elapsed_time = -9999.000000). Resetting the tube state to HOT to reduce risk to the tube.

Error: 245176 The call to the tubeCooled tube cooling library function failed. See long description for complete error Mon Nov 20 21:50:29 2006 Error: 245176 Host: lder Process: scanmgr File: start_scanning.cxx Line: 280 Function: System Control : Scan Control Scan Type: Not scanning Scan: 50001/1/0 Scan Seq Id: 3 The call to the tubeCooled tube cooling library function failed

Error: 245055 Calculating the tube cooling delay failed (status 0). See Long Description for complete error Wed Dec 3 13:50:29 2008 Error: 245055 Host: bay99 Process: scanmgr File; tube_cooling.cxx Line: 1559 Function: System Control :

Applies to

Models
Discovery
Product
Discovery CT750 HD V40_PS_HD64_G_GTL V40_PS_HD64_G_GTM Discovery HD CT750 Method of visual identification HD gantry: Gray top and Gray Side covers with HD Markings Console Type: GOC6 has black SCIM and tower face Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) -h or –help = Outputs complete details about all the available switches associated with swhwinfo swhwinfo –c –m –o -da List of softwares the product can run (Consult attached FCT Software Cross Reference): 08MW39.4 - M3 (see attachement for M3 available options) 09MW29.14 - M4 (HD Options = M3 plus Gemstone Spectral Imaging, Gemstone Spectral Review and volume Helical Shuttle ) Example: Of difference with options software [insite@ct01 ~]$ swokinstall -p Product Software Option Keys: Gemstone Spectral Imaging Permanent HelicalShuttle Permanent Xtream Recon Permanent FAQ's Table weight limit: 500 lbs Tube Type - D3702T Green D3701T Current production - M4 Refer to product data sheets or Technical reference Manual, English 5317222-1EN Revision : 2 or later Refer to Application Tips and Work-Arounds Direction 5311815-1EN Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Software
08MW39.4 for Discovery CT750 HD 08MW39.4 for Discovery CT750 HD 11/17/2008 Inital M3 release. 08MW39.4 for Discovery CT750 HD 11/17/2008 Inital M3 release. - Discovery CT750 HD Collector 5323588 Rev 3 includes OS and Application CD's - Operating System Linux 5.3.8 Software CD 5323584 Rev 1 - Application CT750 HD DVD 5323585 Rev 3 ======================================================= - Class C CT750 5233586 Rev 1 - Class M CT750 5323587 Rev 1 An On-site / Remote identification aid . (Example: check_config) Result from check_config or swhwinfo: 08MW39.4.V40_PS_HD64_G_GTM 08MW39.4.V40_PS_HD64_G_GTL
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.