GE Healthcare · CTBrightSpeedVCT260118362956559655956559630956507840956466275956515840
BrightSpeed HPower, Delight, Velocity or MERI HPower
Symptom
Scanner Hardware Stopped Scan. Scanner Hardware Stopped Scan
Error message
Error: 260118362 Rotor Event Timestamps See Long Description for details Mon Jan 22 15:11:07 2007 Error: 260118362 Host: orp Process: orp_subsys File: gen_exec.c Line: 484 Mon Jan 22 15:11:06 2007 Host : On-Board Rotating Processor Ermes # : 260118362 Exception Class : Secondary Severity : Sec/Soft File : gen_exec.c Line# : 484 Function : No System Function Reported Scan Type : Axial Scan: 4987/2/1 Rotor Event Timestamps(mS) Cur Time: 956559655 Rx: 956559630 Active Scan: 0 ExpDly End: 956559630 Accel: 956507840 Run: 956466275 Accel Time: 6000 Decel: 956515840 Stop: 956516025 Decel Time: 185 No More Rx: 956555175 End Exam: 956146975 Error: 260118363 Rotor Timers See Long Description for details Mon Jan 22 15:11:07 2007 Error: 260118363 Host: orp Process: orp_subsys File: gen_exec.c Line: 494 Mon Jan 22 15:11:06 2007 Host : On-Board Rotating Processor Ermes # : 260118363 Exception Class : Secondary Severity : Sec/Soft File : gen_exec.c Line# : 494 Function : No System Function Reported Scan Type : Axial Scan: 4987/2/1 Rotor Timers Rotor Off Delay Rem(mS): 0 Rotor On Delay Rem(mS): 0 Filament Off Delay Rem(mS): 0 Filament On Delay Rem(mS): 0 Error: 260118177 Jedi (40-0114)Rotor not
Applies to
- Models
- BrightSpeed, VCT
- Product
- BrightSpeed HPower, Delight, Velocity or MERI HPower HP_P_G4_G_HPT Excel HP_P_G8_G_HPT Edge HP_P_G16_G_HPT Elite HP_P_G16_G_GMV Elite HP_P_P16_G_GMV Elite HP_P_M16_G_HPT BrightSpeed Method of remote software hardware identification check_config swhwinfo List of Supported Console Types : HP_P_G16_ G _HPT Note: G could be GRE, AIO or TIO - check with: cat /usr/g/config/INFO | grep CONSOLETYPE GOC4 AIO TIO List of softwares the product can run: 08BW20.1 07MW11.10 08BW44.1 ( Delight ) 09HW30.4 ( Velocity ) 09BW35.11 ( MERI - Pancake DAS ) FAQ's 1. All BrightSpeed Power Systems use the Performix tube D3186T HP_P_G4_G_HPT (Excel - H-Power Table) HP_P_G8_G_HPT (Edge -H-Power Table ) HP_P_G16_G_HPT (Elite -H-Power Table ) HP_P_G16_G_GMV (Elite -Global Table Mid Value - modified GT1700 no IMS ) Note: G could be GRE, AIO or TIO (check with: cat /usr/g/config/INFO | grep CONSOLETYPE ) BrightSpeed Elite Power Systems will only be sold as Velocity System starting in 2Q/2010. Delight Elite Power being phased out 1Q/2010 BrightSpeed Power 4 & 8 slice systems have been discontinued due to restructuring of the product lineup. Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required