Pular para o conteúdo principal
GE Healthcare · CT

Scanner Hardware Stopped Scan.

Symptom

Scanner Hardware Stopped Scan. Scanner Hardware Stopped Scan

Error message

Error: 2109H (265) - X-ray KV command loop out of tolerance See LD for the full error 2109H (265) - X-ray KV command loop out of tolerance This fault is issued when the KV servo command feedback is not within a window. (This feedback from the D/A - A/D loop).

Applies to

Product
HiLight Advantage HLA Hilight Advantage with Genesis Common Console and 9800 Gantry HLA Hilight Advantage Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Component
46-230218P2 20A, 80V, NPN DARLINGTON Transistor 46-230218P2 20A, 80V, NPN DARLINGTON Transistor 46-230218P2 20A, 80V, NPN DARLINGTON Transistor Part #: 46-230218P2 Part Type: GP CONSUMABLES Part Weight: 0.01 LBR Repairable: No Returnable: No Hazardous Material: N Description: 20A, 80V, NPN DARLINGTON TRANSISTOR. FRU: Yes Status: Orderable Comments: FLS - STOCK OF 52647 ALL GONE 46-230218P5 20A, 80V, PNP DARLINGTON TRANSISTOR 46-230218P5 20A, 80V, PNP DARLINGTON TRANSISTOR 46-230218P5 20A, 80V, PNP DARLINGTON TRANSISTOR Part #: 46-230218P5 Part Type: GP CONSUMABLES Part Weight: 0.45 LBR Repairable: No Returnable: No Hazardous Material: N Description: 20A, 80V, PNP DARLINGTON TRANSISTOR. FRU: Yes Status: Orderable Comments: FLS - REPLACES 52648 CAN BE SUBSTITUTED FOR CGA-61902-1 2N6052 2N6286 . 46-170212P1 ADHESIVE THERMAL JOINT COMPOUND 46-170212P1 ADHESIVE THERMAL JOINT COMPOUND 46-170212P1 ADHESIVE THERMAL JOINT COMPOUND Part #: 46-170212P1 Part Type: GP CONSUMABLES Part Weight: 0.45 LBR Repairable: No Returnable: No Hazardous Material: N Description: ADHESIVE FRU: Yes Status: Orderable Comments: FLS - THERMAL JOINT COMPOUND - SHELFLIFE IS 5 YEARS. THIS MATERIALIS NON-HAZARDOUS PER THE MSDS.THE MANUFACTURER IS WAKEFIELD ENGINEERING. MS4183 6/26/97 2-OZ JAR (OPAQUE WHITE GREASE) SAME AS 46-214910P1 PER PCN 184375. C. BRICKLER 9/6/94 CHANGED TO FRU 1 PER PCN 220363. ADDED BY MS20544, CSV ON 12/30/01. ALSO CALLED HEAT SINK COMPOUND
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.