Fails TPS Reset when booting up to Applications or when Resetting TPS Due To 48V Power Supply 1000W.
Symptom
Fails TPS Reset when booting up to Applications or when Resetting TPS See Long Description When the MR system is booting up to applications it will fail TPS reset but Applications will successfully boot. With Applications up and "Reset TPS" has been selected, TPS fails to download successfully.
Error message
2267503 DTX1 Calibration Data Collection Failure Calibration of the DTX1 failed because the Irf3 could not collect sample data from the 1st RRX module. This could be a communication failure or an analog signal so large it overflowed the RRX See Long Description 2267503 MOI_MR diagCoord dtxCal.cpp 259 Task ID: 0x47da0b0 Time: 40817 Object: AGP Exception Class: Notification Function: Software/Firmware/Config: N/A DTX1 Calibration Data Collection Failure Calibration of the DTX1 failed because the Irf3 could not collect sample data from the 1st RRX module. This could be a communication failure or an analog signal so large it overflowed the RRX.-> Extended Error: DTX calibration uses the Irf3 board to collect sample data from the 1st RRX module. The DTX calibration failed because the data collection from the RRX failed at least one time. This could indicate a problem with the RRX, the Irf3, or the clock and data fiber cables that connect these devices together.
Applies to
- Models
- Discovery
- Product
- Discovery MR450 Also called DVMR. This product is compatible with 1.5T 20.1, 20.1_IB1, IB2, 21.0 and DV22.0 software systems only.
- Software
- DV22.0 For the Discovery MR750, MR450 or Optima MR450w products only. For the Discovery MR750, MR450 or Optima MR450w products only.
- Component
- 5140621-4 48V Power Supply 1000W Condor PN GPMP 900_48 TEAL PN 0870109 5140621-4 48V Power Supply 1000W Condor PN GPMP 900_48 TEAL PN 0870109. Part is being set up for 3.0T DVMR program RSPL. 501139061, 5-Mar-08.
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- CWA How to Change Date or Time on LX, Excite, HD, HDe, HDx, HDxT, HFO, Excite HFO, Ovation1-4, Profile1-5, Discovery MR450 MR750 and Optima 450w Systems.
- CWA No Power to the Table and Magnet Display, Table Will Not Move And No Lights On the Magnet.
- CWA How to Change Exam Number from Remote Tools.
- Known Software issue with 15M4B coding error.
- Unable to Send Images to the PACS Due to PACS is down.
- U41 of the Slave RF Ctrl Assy, part of the PSU in the SRFD2 RF Amplifier Failed.