GE Healthcare · CTLightSpeed2300110084680001115223748718327
LightSpeed 2.X (Plus, QX/i) - Octane
Symptom
"Scan hardware Stopped Scan" with scan data errors. "Scan hardware Stopped Scan" with scan data errors
Error message
Error: 230011008 Unable to remove scan file from scan data disks. Error: 230011008 Unable to remove scan file from scan data disks Error: 230011008 Unable to remove scan file from scan data disks. Wed May 4 16:25:48 2005 Error: 230011008 Host: gsgect2 Process: scanmgr File: sdio_xfs_io_ops.c Line: 1164 Function: Data Acquisition : SBC Processing Scan Type: Axial Scan: 2800/200/3 Scan Seq Id: 468000 Unable to remove scan file from scan data disks. Scan: CT02/2800/200/3 Scan file: /raw_data/ex2800.CT02.1115223748.718327/ov.s200a3 OS error : 140 --- Remote I/O error Scan file may be deleted manually.
Applies to
- Models
- LightSpeed
- Product
- LightSpeed 2.X (Plus, QX/i) - Octane Always S-DAS 2.4.2_H2.4M5 LightSpeed 2.X (Plus, QX/i) - Octane (Pegasus or Rhapsode IG) - Always S-DAS Method of visual identification Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config List of Supported Console Types Octane with Pegasus Recon hardware. List of softwares the product can run 2.4.2_H2.4M5 FAQ's Table weight limit - Up to 400 lb. (180 kg) with ± .25 mm positional accuracy. 450Ib (205 kg) max weight Tube type - D3186T Current production details - See Technical Reference Manual found on the Common Document Library Tips and workarounds, where to find it - Common Document Library(CDL) . Search for the latest FMI software release. In the furnished materials will be the list of various manuals with part numbers for the various languages. Example: English versions 2211223-100 FEATURES/OPTIONS STD/OPTION Cat # Digital Laser Camera I/F B7700PD Smart Helical (s/w only) Standard B7530TK Fast Recon (s/w only) Option B7700JF BMD (requires B7710MP or MN) Option B7710MK Smart Prep Option B7530SP Smart Score ? ? 3D Analysis (Requires D3D) Option B7540TD Navigator (s/w only) Option B7540N DentaScan (s/w only) Option B7540SD Direct 3D (Requires B7710SA) Option B7810SS HIS/RIS Option (h/w and s/w) Option B7500PN Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Component
- 2225004-10 73 GB destroked to 18GB 15000 Used on Octane OC with 9Gb OS hard drive. See Long Description for more detail. This part is used on Octane Operators Consoles that have a 9Gb OS hard drive and need a destroked Scan Data Disk. See SN0711061b for jumper settings. Part #: 2225004-10 Part Type: GP CONSUMABLES Part Weight: 0.00 LBR Repairable: No Returnable: No Hazardous Material: N Description: 73 GB destroked to 18GB 15000 RPM Scan Data Drive FRU: Yes Status: Orderable 2191454-3 SCSI Cable used on LightSpeed H1& H2 Systems See LD for details Part #: 2191454-3 Part Type: GP CONSUMABLES Part Weight: 0.91 LBR Repairable: No Returnable: No Hazardous Material: N Description: SCSI CABLE, DRV BOX TO S/BLKHD, HD68 FRU: Yes Status: Orderable Comments: FLS - SCSI CABLE, DIV BOX TO S/ BH HD68. REPLACES 2191454-2 PER PCN 199904. USE UP OLD FIRST.USED ON H1 AND H2. MS26561 DSM 11/7/00 *PER CT MFG - THEY NO LONGER STOCK THIS AT CT AS IT IS OBSOLETE TO CT - 1/29/03 - MS22763-JP* MUST OBTAIN FROM NORTECH LightSpeed QXi with no O2 or original H2 Systems with HSD in Dog cage: Bulkhead J51 to Drive Box (Molded) is 2191454-3
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required