LightSpeed 7.x (VCT, VCT Select, Pro32)

Symptom

Scan aborts with table cradle not moving during scan Scan aborts and table cradle not moving during scan with Error: 260134634 Tue Sep 27 16:15:22 2005 Error: 260134634 Host: tgp Process: tgp_subsys File: gtcb_cmc_profile.cxx Line: 537 Tue Sep 27 16:15:23 2005 Host : Table Sub-System Ermes # : 260134634 Exception Class : Secondary Severity : Pri/Soft File : gtcb_cmc_profile.cxx Line# : 537 Function : No System Function Reported Scan Type : None/Unknown Scan: 0/0/0 Cradle task received invalid corrected speed from cradle monitor task. received 284000 um/s expected 1 to 225000 um/s

Error message

Error: 260125041 Uncommanded Table Motion with the Ims drive. See long description for a sample error. Tue Nov 10 13:27:23 2009 Error: 260125041 Host: tgp Process: tgp subsys File: ta callback gt.c Line: 521 Tue Nov 10 13:27:24 2009 Host : Table Gantry Processor Ermes # : 260125041 Exception Class : Secondary Severity : Pri/Soft File : ta callback gt.c Line# : 521 Function : No System Function Reported Scan Type : Scout Scan: 12678/1/1 Uncommanded Table Motion with the Ims drive. Current pos:400840 um Last stop pos:400000 um Tolerance:500 um Time since last stop:360 ms Last target pos:400000 um Hardware status:0 Another drive (Elevation or Cradle) pos:902985 um

Applies to

Models
LightSpeed, VCT, BrightSpeed
Product
LightSpeed 7.x (VCT, VCT Select, Pro32) V40_H_V64_G_GTM V40_H_V64_G_GTL V40_H_V32_G_GTM V40_H_V32_G_GTL V40_H_H64_G_GTM V40_H_H64_G_GTL V40_H_HS64_G_G Product Name: LightSpeed 7.x (VCT, VCT Select, Pro32) Product photographs Method of remote or software identification - See attachment for a complete list of software commands and typical results. check_config swhwinfo “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) · -h or –help = Outputs complete details about all the available switches associated with swhwinfo · swhwinfo –c –m –o -da List of Supported Console Types GOC5 Will have a VDARC and VIG GOC6 Will have a VDIG List of softwares the product can run 09MW08.10 09MW08.11 08MW33.2 07MW18.4 06MW03.4 05MW31.6 FAQ's Table weight limit - Up to 500 lb. (227 kg) with ± .25 mm positional accuracy Tube type - D3194T D3193T(green) Current production - M4 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system. Done acording to template
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.