GE Healthcare · CTLightSpeedVCT122561100214974
LightSpeed 1.X - GRE
Symptom
Cannot network / transfer images. Cannot network / transfer images
Error message
Error: (dcspush.c:1075) Remote Host cpct is Down - Retry after next retry_interval SEEN in dcslog /export/home/ctuser/logfiles/dcslog See Long Descripion for complete error Error: (dcspush.c:1075) Remote Host cpct is Down - Retry after next retry_interval SEEN in dcslog /export/home/ctuser/logfiles/dcslog MESSAGE from Process 12256>> Mon Sep 12 08:11:33 2005 (dcspush.c:1075) Remote Host cpct is Down - Retry after next retry_interval Error: 11002 DCM low level error: Network error (508): Network error (114) see long description for full error detail. Error 11002 found in gesyslog as well as other errors in /usr/g/ctuser/logfiles/dcslog gesyslog error: Thu Oct 29 14:04:48 2009 Error: 11002 Host: ct01 Process: dcserver File: dcscommon.c Line: 228 DCM low level error: Network error (508): Network error (114) dcslog errors: MESSAGE from Process 6940>> Thu Oct 29 10:01:30 2009 (dcscommon.c:228) [Dcserver]> DCM low level error: Network error (508): Network error (114) MESSAGE from Process 6940>> Thu Oct 29 10:01:30 2009 (dcspush.c:1012) Remote Host 918231UTEA is Down - Retry after next retry_interval MESSAGE from Process 14974>> Thu Oct 29 14:04:48 2009 (dcscommon.c:228) [Dcserver]> DCM
Applies to
- Models
- LightSpeed, VCT
- Product
- LightSpeed 1.X - GRE H1_P_S4 Lightspeed 1.X - GRE Method of visual identification Large square gantry similar in appearance to a CTi gantry. Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config “swhwinfo” will have the following new switches available with the VCT M4 and PF 1.5 M3 software release (software release deploying this “swhwinfo” capability is “06MW03.?”): · -c or -classc = Outputs the Class C version, if installed, on the system · -m or -classm = Outputs the Class M version, if installed, on the system · -o or -os = Outputs the Operating System version installed on the system · -da or -date = Outputs the date and time the software was installed on the system (LFC) -h or –help = Outputs complete details about all the available switches associated with swhwinfo swhwinfo –c –m –o -da List of Supported Console Types GOC3 Will have a DARC, SDDA and IG GOC4 Will have a DARC 2 and IG List of softwares the product can run 07MW11.10 SP3 06MW29.7 - obsolete 06MW03.5 - obsolete 05MW14.5 - obsolete 04MW44.9 - obsolete 04MW13.7 - obsolete FAQ's Table weight limit - Up to 400 lb. (180 kg) with ± .25 mm positional accuracy. 450Ib (205 kg) max weight Tube type - D3176T Current production details - See Technical Reference Manual found on the Common Document Library Tips and workarounds, where to find it - Common Document Library(CDL) . Search for the latest FMI software release. In the furnished materials will be the list of various manuals with part numbers for the various languages. Example: English versions 2211223-100 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required