GE Healthcare · CTBrightSpeed
BrightSpeed HPower, Delight, Velocity or MERI HPower
Symptom
Intermittent single ring artifact. See Long Description for more images. Interemittent single ring artifact.
Applies to
- Models
- BrightSpeed
- Product
- BrightSpeed HPower, Delight, Velocity or MERI HPower HP_P_G4_G_HPT Excel HP_P_G8_G_HPT Edge HP_P_G16_G_HPT Elite HP_P_G16_G_GMV Elite HP_P_P16_G_GMV Elite HP_P_M16_G_HPT BrightSpeed Method of remote software hardware identification check_config swhwinfo List of Supported Console Types : HP_P_G16_ G _HPT Note: G could be GRE, AIO or TIO - check with: cat /usr/g/config/INFO | grep CONSOLETYPE GOC4 AIO TIO List of softwares the product can run: 08BW20.1 07MW11.10 08BW44.1 ( Delight ) 09HW30.4 ( Velocity ) 09BW35.11 ( MERI - Pancake DAS ) FAQ's 1. All BrightSpeed Power Systems use the Performix tube D3186T HP_P_G4_G_HPT (Excel - H-Power Table) HP_P_G8_G_HPT (Edge -H-Power Table ) HP_P_G16_G_HPT (Elite -H-Power Table ) HP_P_G16_G_GMV (Elite -Global Table Mid Value - modified GT1700 no IMS ) Note: G could be GRE, AIO or TIO (check with: cat /usr/g/config/INFO | grep CONSOLETYPE ) BrightSpeed Elite Power Systems will only be sold as Velocity System starting in 2Q/2010. Delight Elite Power being phased out 1Q/2010 BrightSpeed Power 4 & 8 slice systems have been discontinued due to restructuring of the product lineup. Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Component
- 2371627-4 replaces 2371627-3 GDAS / MDAS 16 Slice RIGHT Backplane Chassis Asm EDITION 1-2 See LD for FEMC comments 2371627-4 replaces 2371627-3 GDAS / MDAS 16 Slice RIGHT Backplane Chassis Asm EDITION 1-2 Part #: 2371627-4 Part Type: GP CONSUMABLES Part Weight: 2.18 LBR Repairable: No Returnable: No Hazardous Material: N Description: GDAS-MDAS 16 Slice RIGHT BP-Chassis Asm EDITION 1-2 FRU: Yes Status: Orderable Comments: Added as replacement for 2371627, -2, -3 & 2332630 per ecr 2012678, ms13452 050518 Part #: 2371627-3 Part Type: GP CONSUMABLES Part Weight: 0.00 LBR Repairable: No Returnable: No Hazardous Material: N Description: BP-Chassis Right EMC Asm - GDAS FRU: Yes Status: Orderable Comments: 2371627-3 is backward compatible replacement for 2371627-2. DO NOT USE 2371627-2 to replace 2371627-3. 2371627-3 is EMC2 Compliant. ms13452 PART ADDED PER VCT RSPL AND IS EMC2 COMPLETE MS8336 12/08/2004
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required