GE Healthcare · CTLightSpeedVCT260112013

LightSpeed 5.X (60kW)

Symptom

Unable to do a scout scan. Table moves to scan postion, but the green light in the Start Scan button on SCIM never flashes. See Long Description for details Unable to do a scout scan. Table moves to scan postion, the Start Scan light does not illuminate, or the Start Scan illuminates but when pressed nothing happens, or the Start Scan light illuminates solid (normally it flashes / blinks ). After rebooting the CT, or reseting the Scan Hardware one of the Gantry Control panels (keypads) is blinking / flashing [Err] When the scanner is ready to scan the green light in the Start Scan button (on the SCIM at the console) should start flashing (blinking) indicating you should push it to start the scan. The green light in the button never lights. A few different scenarios can happen 1) (Scout) Move to scan lights, when pressed table moves into position, but The <Start Scan> light never flashes to telling you to start the scan. If <Pause> is clicked on the scan screen then the <Start Scan> button will light (not flash), but when pushed scanner does not scan. 2) The <Start Scan> button lights, but when <Start Scan> is pushed scanner does not scan. <Pause> is the only button selectable on the scan screen. When <Pause> is clicked the loop starts over with the <Start Scan> button lighting, but when pressed again the scanner does not scan 3) The <Start Scan> button lights solid (normally it flashes / blinks), when pressed scanner does not scan After the CT has been rebooted, or if the Scan Hardware was reset, the CT still will not scan. The customer notices that [Err] is flashing on one of the Gantry Controls.

Error message

Error: 260112013 Stopping SCAN because the GUIF Alignment Lights button has been pressed See long description for full error Fri Oct 19 09:20:03 2007 Error: 260112013 Host: tgp Process: tgp_subsys File: uif_table_tilt_mgr_gt.c Line: 8749 Fri Oct 19 09:20:03 2007 Host : Table Gantry Processor Ermes # : 260112013 Exception Class : Operator Abort Severity : Primary File : uif_table_tilt_mgr_gt.c Line# : 8749 Function : No System Function Reported Scan Type : Scout Scan: 9477/1/1 Stopping SCAN because the GUIF Alignment Lights button has been pressed

Applies to

Models
LightSpeed, VCT
Product
LightSpeed 5.X (60kW) LightSpeed 5.X (60kW) ~ Use with MDAS or GDAS HP_P_G4 HP_P_G8 HP_P_G16 HP_P_M16 LightSpeed 5.X 60KW G-DAS16 with GRE Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.