Scan aborts with table cradle not moving during scan

Symptom

Scan aborts with table cradle not moving during scan Scan aborts and table cradle not moving during scan with Error: 260134634 Tue Sep 27 16:15:22 2005 Error: 260134634 Host: tgp Process: tgp_subsys File: gtcb_cmc_profile.cxx Line: 537 Tue Sep 27 16:15:23 2005 Host : Table Sub-System Ermes # : 260134634 Exception Class : Secondary Severity : Pri/Soft File : gtcb_cmc_profile.cxx Line# : 537 Function : No System Function Reported Scan Type : None/Unknown Scan: 0/0/0 Cradle task received invalid corrected speed from cradle monitor task. received 284000 um/s expected 1 to 225000 um/s

Error message

Error: 260115185 Cradle velocity is out of tolerance Error. 260115185 Cradle velocity is out of tolerance cradle_position(um) : 1272744 target_position(um) : 1349271 velocity (um/s) : 75000 fpga status : 0x8104

Error: 260100042 Cradle was NOT ready See the long description for the full error code Tue May 17 16:02:03 2005 Error: 260100042 Host: tgp Process: tgp_subsys File: scHdwRdy.c Line: 70 Tue May 17 16:02:02 2005 Host : Table Gantry Processor Ermes # : 260100042 Exception Class : Soft Severity : Sec/Soft File : scHdwRdy.c Line# : 70 Function : No System Function Reported Scan Type : Scout Scan: 106/1/1 Cradle was NOT ready

Applies to

Models
LightSpeed
Product
LightSpeed RT4 WB O G4 G HPT WB O M4 G HPT LightSpeed RT4 with GRE and MDAS4 or GDAS4 gantry At GE Medical Systems, we’re pioneering exciting CT technology for Radiation Therapy planning. Introducing the newest addition to our LightSpeed® series – LightSpeed RT, the first multi-slice, wide-bore CT scanner with the largest field of view in the industry. With a generous 80 cm gantry opening, the LightSpeed RT bore is 10 cm larger than conventional scanners. This provides complete flexibility for patient positioning freedom – even for the most demanding oncology needs. And the 65 cm variable field of view delivers 15 additional centimeters of visual coverage, allowing clinicians to see a patient’s entire anatomy for precise radiation therapy planning. Position and precision Thin, multi-slice imaging is the extra bonus – enabling respiratory gating, providing precise target delineation and delivering higher resolution digitally reconstructed radiographs (DRRs) than ever before. All adding up to the ability for you to deliver what really matters most – better cancer care for your patients. Plus, the LightSpeed RT scanner is available with the Exact™ couch insert, enabling you to consistently replicate patient immobilization for treatment. With LightSpeed RT, the future of your Radiation Oncology department is wide open. Links to the Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
Area
CT

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required

Related GE Healthcare CT issues