GE Healthcare · CTLightSpeed18260751200
LightSpeed 2.X (Plus, QX/i) - Octane
Symptom
Gantry tilt moves a small distance then stops (less than 2 deg) Gantry tilts forward a small distance then stops
Error message
Error: 182607 HW/SW error: Tilt Velocity tracking See LD for more details Thu May 11 23:04:54 2006 Error: 182607 Host: ETC Process: Tilt File: CmdMotion.c 1.21 2/17/95 Line: 139 Function: PATIENT ANATOMY POSITIONING : Elevation - Tilt Scan: 51200/1/0 Type: None/Unknown Exception Level: Pri/Soft Time: 23:04:53:540 Log Series: 144 HW/SW error: Velocity tracking error. Actual Velocity 150 (.01 deg/sec) Expected Velocity 100 (.01 deg/sec) Tol 40 (.01 deg/sec) Cur Pos -1194 (.01 deg) Tilt Dir: 1 (0 = BCK 1 = FWD) . INFO: Probable Problem could be 180V Power is LOW.
Applies to
- Models
- LightSpeed
- Product
- LightSpeed 2.X (Plus, QX/i) - Octane Always S-DAS 2.4.2_H2.4M5 LightSpeed 2.X (Plus, QX/i) - Octane (Pegasus or Rhapsode IG) - Always S-DAS Method of visual identification Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config List of Supported Console Types Octane with Pegasus Recon hardware. List of softwares the product can run 2.4.2_H2.4M5 FAQ's Table weight limit - Up to 400 lb. (180 kg) with ± .25 mm positional accuracy. 450Ib (205 kg) max weight Tube type - D3186T Current production details - See Technical Reference Manual found on the Common Document Library Tips and workarounds, where to find it - Common Document Library(CDL) . Search for the latest FMI software release. In the furnished materials will be the list of various manuals with part numbers for the various languages. Example: English versions 2211223-100 FEATURES/OPTIONS STD/OPTION Cat # Digital Laser Camera I/F B7700PD Smart Helical (s/w only) Standard B7530TK Fast Recon (s/w only) Option B7700JF BMD (requires B7710MP or MN) Option B7710MK Smart Prep Option B7530SP Smart Score ? ? 3D Analysis (Requires D3D) Option B7540TD Navigator (s/w only) Option B7540N DentaScan (s/w only) Option B7540SD Direct 3D (Requires B7710SA) Option B7810SS HIS/RIS Option (h/w and s/w) Option B7500PN Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Component
- 2227239 Hydraulic fluid (crosses to P/N Z9807QD, .5 L Hydraulic Oil) See Long Description for details 2227239 Hydraulic fluid (crosses to P/N Z9807QD, .5 L Hydraulic Oil) Part #: Z9807QD Part Type: GP CONSUMABLES Part Weight: 3.00 LBR Repairable: No Returnable: No Hazardous Material: N Description: 0IL ASSY FRU: Not Available Status: Orderable ====================== Parts Offered as: Current: Z9807QD Harvested: Not Available Exchange: Not Available Comments: FLS - PLEASE ORDER AS YMSZ9807QD MS13452
- Area
- CT
Full cause & step-by-step resolution