GE Healthcare · CTLightSpeedVCT20000043620018001916851
LightSpeed 3.X (Ultra, Plus, QX/i) - Octane
Symptom
No dose report created with exams.
Error message
Error: 200000436 Image not installed because image available event flagged image as not being available. Fri May 27 09:40:15 2005 Error: 200000436 Host: ct2 Process: dms File: InstallImage.cxx Line: 1113 Image 4243/1/1 not installed because image available event flagged image as not being available. Error: 200180019 Dose Report command failed See long description for a full sample error message. Tue Oct 7 14:31:32 2008 Error: 200180019 Host: ccct Process: scanRx File: Ctdi.cxx Line: 829 Dose Report command failed: /usr/g/ctuser/DoseReport/dosereport "/usr/g/ctuser/D oseReport/seed.dcm" "/usr/g/sdc image pool2/reserved/IMSseQGEa000Q7/" " /usr/g/se rvice/log/scanRx" "1" "16851" &. Status=-1. Tue Oct 28 11:45:44 2008 Error: 200180019 Host: mdct Process: dosereport File: dosereport.c Line: 189 Dose Report command failed: Bad Return Status. Status=127.
Applies to
- Models
- LightSpeed, VCT
- Product
- LightSpeed 3.X (Ultra, Plus, QX/i) - Octane Always 4 or 8 slice MDAS 308i.2_H3.1M5 LightSpeed 3.X - Octane Method of visual identification Method of remote or software identification - See attachment below for a complete list of software commands and typical results. check_config List of Supported Console Types Octane with Pegasus Recon hardware. List of softwares the product can run 308I.2_H3.1M5 305.4_H3.1M4 - obsolete 303.1_H3M4 - obsolete FAQ's Table weight limit - Up to 400 lb. (180 kg) with ± .25 mm positional accuracy. 450Ib (205 kg) max weight Tube type - D3186T Current production details - See Technical Reference Manual found on the Common Document Library Tips and workarounds, where to find it - Common Document Library(CDL) . Search for the latest FMI software release. In the furnished materials will be the list of various manuals with part numbers for the various languages. Example: English versions 2211223-100 Options - TBD Links to the updated Product Service Manuals, FMIs, Service Notes, Option Manuals and Operator Documents can be found online at the attached sites. Always use the most appropriate documentation for your system.
- Area
- CT
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy and the attached service documents for this GE Healthcare CT issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required