Customer is performing chiller maintenance or repairs.MAC00017 PDS Alarm Compressor water supply fault caused by the com…

Customer is performing chiller maintenance or repairs.MAC00017 PDS Alarm Compressor water supply fault caused by the combination of water flow and temp being out of spec.During Scheduled Chiller Maint…

Symptom

MAC00017 PDS Alarm Compressor water supply fault caused by the combination of water flow and temp being out of spec. The OnWatch engine has determined that the water supply to the coldhead compressor from the chiller is out of specifications. The combination of water flow and water temperature parameters is out of specifications. NOTE: The Digital Services (DS) Rules Engine detected this problem. This issue is only applicable when detected in this way, and should not be reused in Knowledge objects for normal reactive service. This is an automated alarm generated by the OnWatch program. An algorithm was run on the data uploaded from the MM3 into Insite2. The data shows that the water flow and water temperature as individual vales are with in specifications, But the combination of the 2 parameters is out of specifications. The OnWatch engine algorithm used the engineering specifications supplied by the manufacturer of the compressor, Sumitomo. This alarm needs to be resolved to extend the Coldhead and compressor lifespan. Refer to the latest appropriate service documentation here MR Service Documentation .

Error message

MAC00017 PDS Alarm Compressor water supply fault caused by the combination of water flow and temp being out of spec. The OnWatch engine has determined that the water supply to the coldhead compressor from the chiller is out of specifications. The combination of water flow and water temperature parameters is out of specifications. NOTE: The Digital Services (DS) Rules Engine detected this problem. This issue is only applicable when detected in this way, and should not be reused in Knowledge objects for normal reactive service. This is an automated alarm generated by the OnWatch program. An algorithm was run on the data uploaded from the MM3 into Insite2. The data shows that the water flow and water temperature as individual vales are with in specifications, But the combination of the 2 parameters is out of specifications. The OnWatch engine algorithm used the engineering specifications supplied by the manufacturer of the compressor, Sumitomo. This alarm needs to be resolved to extend the Coldhead and compressor lifespan. Refer to the latest appropriate service documentation here MR Magnet Service Documentation

Applies to

Product
Magnet Monitor SHeM Advantech. Part Number: 2219400 (OBSOLETE, changes up to a MM3, 2394952 as of July, 2006) Modem Cable: 2276568 MultiTech Modem: 2245794 Magnet Monitor Proprietary Software: 2252032-3 See the Long Description for the link to download the following 4 manuals; LCC Magnet Mon. Hardware Install: 2230681 LCC ProActive Software Install & T/S: 2236995 HFO Magnet Mon. Hardware Install: 2261116 HFO ProActive Software Install & T/S: 227721 Proprietary, For GE Healthcare personnel Only This information is Property of GE Healthcare - For GE Healthcare Service Personnel Only. Disclosure to Third Parties Prohibited. Click on this link to reach the Magnet Service Documentation CD-Rom on the MR Engineering Service Documentation website. Part Number : 2219400 ( OBSOLETE , changes up to a MM3, 2394952 as of July, 2006 ) Modem Cable : 2276568 MultiTech Modem : 2245794 Magnet Monitor Proprietary Software : 2252032-3 The following 4 manuals may be downloaded from the above Magnet CD-Rom link. LCC Magnet Mon. Hardware Install: Direction 2230681 LCC ProActive Software Install & T/S: Direction 2236995 HFO Magnet Mon. Hardware Install: Direction 2261116 HFO ProActive Software Install & T/S: Direction 2277211
Software
SHeM Proprietary Software 2.3.7. SHeM Proprietary Software 2.3.7 SHeM Proprietary Software 2.3.7.
Area
MR

Full cause & step-by-step resolution

The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.

7-day free trial · no credit card required

Related GE Healthcare MR issues