GE Healthcare · MRSigna2244842224459022448602244591
2244860 The GP is reporting a SGA Power Supply OverCurrent Fault and/or Error 2244842 The GP reported multiple SGA Power…
2244860 The GP is reporting a SGA Power Supply OverCurrent Fault and/or Error 2244842 The GP reported multiple SGA Power Supply Overcurrent Faults due to HFA.
Symptom
Will Not Scan with Gradient Errors.
Error message
2244842 The GP reported mutiple SGA Power Supply Overcurrent Faults.-> See Long Description 2244842 LXM2 NSP SCP:Grad 3064 Exception Class: Unknown Severity: Unknown Function: Gradient: N/A PSD: Unknown Coil: Unknown Scan: -1/-1 The GP reported mutiple SGA Power Supply Overcurrent Faults.-> Extended Error: Look at SGA PS OC LEDs on the front of the module to determinewhich axis caused the fault. If the Primary OC LED is lit, replace theSGA Power Supply. If a secondary OC LED is lit, swap militaryconnectors to the Gradient Amplifiers to isolate Gradient Amplifiervs. SGA Power Supply. For more information, open the Common ServiceDesktop and go to Service Docs - Peripherals - Gradient Electronics 2244590 Extended Help. Note: The word "mutiple" is a misspelling of the word "multiple". It exists as such in software. 2244860 The GP is reporting a SGA Power Supply OverCurrent Fault. Same as 2244860 and 2244590. 2244860 errorcode on Post 14M5 is the same error as 2244590 on 11X, G3 and 2244591 on 12X, E2, 14M4 (HDx, HDe).2244860 "The GP is reporting a SGA Power Supply OverCurrent Fault.
Applies to
- Models
- Signa
- Product
- Signa HDxT This product is for 1.5T Signa HDxT systems with 15.0 software and HDi systems with 15.0 software. This product is for 1.5T Signa HDxT systems with 15.0 software and HDi systems with 15.0 software.
- Software
- 15.0 For Product Signa HDxT and HDi only. -- NOT to be used with HDe. -- For Product Signa HDxT and HDi only. -- NOT to be used with HDe. --
- Component
- 5189221-2 HFA-S Assembly with FRU Packaging 5189221-2 HFA-S Assembly with FRU Packaging
- Area
- MR
Full cause & step-by-step resolution
The complete cause analysis, the step-by-step remedy for this GE Healthcare MR issue are available to FSELIB subscribers — re-authored, web-first, searchable.
7-day free trial · no credit card required
Related GE Healthcare MR issues
- CWA How to Change Date or Time on LX, Excite, HD, HDe, HDx, HDxT, HFO, Excite HFO, Ovation1-4, Profile1-5, Discovery MR450 MR750 and Optima 450w Systems.
- CWA No Power to the Table and Magnet Display, Table Will Not Move And No Lights On the Magnet.
- CWA How to Change Exam Number from Remote Tools.
- Known Software issue with 15M4B coding error.
- Unable to Send Images to the PACS Due to PACS is down.
- U41 of the Slave RF Ctrl Assy, part of the PSU in the SRFD2 RF Amplifier Failed.